Evaluation of Marginal Fit of Two Allceramic Copings with Two Finish Lines

Yükleniyor...
Küçük Resim

Tarih

2012

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Objectives: This in-vitro study investigated the marginal fit of two all-ceramic copings with 2 finish line designs. Methods: Forty machined stainless steel molar die models with two different margin designs (chamfer and rounded shoulder) were prepared. A total of 40 standardized copings were fabricated and divided into 4 groups (n=10 for each finish line-coping material). Coping materials tested were IPS e.max Press and Zirkonzahn; luting agent was Variolink II. Marginal fit was evaluated after cementation with a stereomicroscope (Leica MZ16). Two-way analysis of variance and Tukey-HSD test were performed to assess the influence of each finish line design and ceramic type on the marginal fit of 2 all-ceramic copings (? =.05). Results: Two-way analysis of variance revealed no statistically significant differences for marginal fit relative to finish lines (P=.362) and ceramic types (P=.065). Conclusion: Within the limitations of this study, both types of all-ceramic copings demonstrated that the mean marginal fit was considered acceptable for clinical application (?120 ?m). (Eur J Dent 2012;6:163-168)

Açıklama

Anahtar Kelimeler

All-ceramic types, Finish lines, Marginal fit

Kaynak

European Journal of Dentistry

WoS Q Değeri

Scopus Q Değeri

Q1

Cilt

6

Sayı

2

Künye

Subaşı, G., Öztürk, N., İnan, Ö., Bozoğulları, N., (2012). Evaluation of Marginal Fit of Two Allceramic Copings with Two Finish Lines. European Journal of Dentistry, 6(2), 163-168.