Experimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outlet

dc.contributor.authorDincer, K.
dc.contributor.authorBaskaya, S.
dc.contributor.authorUysal, B. Z.
dc.contributor.authorUcgul, I.
dc.date.accessioned2020-03-26T17:38:39Z
dc.date.available2020-03-26T17:38:39Z
dc.date.issued2009
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractIn this study, effects of position, diameter (5, 6, 7, 8 mm) and angle (30 degrees-180 degrees) of a mobile plug, located at the hot outlet side in a Ranque-Hilsch Vortex Tube (RHVT), were determined experimentally for best performance. In addition to plug parameters, effects of supply pressure (200-420 kPa) and number of nozzles (2, 4, 6) were also studied. The internal diameter (D) of the vortex tube used in the experiments was 9 mm; the ratio of the length of the vortex tube to its diameter (L/D) was 15. Four different plug locations were studied. The maximum difference in the temperatures of hot and cold streams was obtained for the plug diameter of 5 mm, tip angles of 30 degrees and 60 degrees, 4 nozzles and by keeping the plug location at the far extreme end. (C) 2008 Elsevier Ltd and IIR. All rights reserved.en_US
dc.description.sponsorshipSelcuk UniversitySelcuk University [2002/124]en_US
dc.description.sponsorshipFinancial support of this study by the research fund of the Selcuk University under Grant No. 2002/124 is gratefully acknowledged.en_US
dc.identifier.doi10.1016/j.ijrefrig.2008.06.002en_US
dc.identifier.endpage94en_US
dc.identifier.issn0140-7007en_US
dc.identifier.issn1879-2081en_US
dc.identifier.issue1en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage87en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.ijrefrig.2008.06.002
dc.identifier.urihttps://hdl.handle.net/20.500.12395/23540
dc.identifier.volume32en_US
dc.identifier.wosWOS:000264917500010en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherELSEVIER SCI LTDen_US
dc.relation.ispartofINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROIDen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectRefrigeration systemen_US
dc.subjectVortex tubeen_US
dc.subjectRanque-Hilschen_US
dc.subjectExperimenten_US
dc.subjectPerformanceen_US
dc.subjectParameteren_US
dc.subjectPipingen_US
dc.subjectGeometryen_US
dc.titleExperimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outleten_US
dc.typeArticleen_US