Experimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outlet
dc.contributor.author | Dincer, K. | |
dc.contributor.author | Baskaya, S. | |
dc.contributor.author | Uysal, B. Z. | |
dc.contributor.author | Ucgul, I. | |
dc.date.accessioned | 2020-03-26T17:38:39Z | |
dc.date.available | 2020-03-26T17:38:39Z | |
dc.date.issued | 2009 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | In this study, effects of position, diameter (5, 6, 7, 8 mm) and angle (30 degrees-180 degrees) of a mobile plug, located at the hot outlet side in a Ranque-Hilsch Vortex Tube (RHVT), were determined experimentally for best performance. In addition to plug parameters, effects of supply pressure (200-420 kPa) and number of nozzles (2, 4, 6) were also studied. The internal diameter (D) of the vortex tube used in the experiments was 9 mm; the ratio of the length of the vortex tube to its diameter (L/D) was 15. Four different plug locations were studied. The maximum difference in the temperatures of hot and cold streams was obtained for the plug diameter of 5 mm, tip angles of 30 degrees and 60 degrees, 4 nozzles and by keeping the plug location at the far extreme end. (C) 2008 Elsevier Ltd and IIR. All rights reserved. | en_US |
dc.description.sponsorship | Selcuk UniversitySelcuk University [2002/124] | en_US |
dc.description.sponsorship | Financial support of this study by the research fund of the Selcuk University under Grant No. 2002/124 is gratefully acknowledged. | en_US |
dc.identifier.doi | 10.1016/j.ijrefrig.2008.06.002 | en_US |
dc.identifier.endpage | 94 | en_US |
dc.identifier.issn | 0140-7007 | en_US |
dc.identifier.issn | 1879-2081 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 87 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.ijrefrig.2008.06.002 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/23540 | |
dc.identifier.volume | 32 | en_US |
dc.identifier.wos | WOS:000264917500010 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER SCI LTD | en_US |
dc.relation.ispartof | INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Refrigeration system | en_US |
dc.subject | Vortex tube | en_US |
dc.subject | Ranque-Hilsch | en_US |
dc.subject | Experiment | en_US |
dc.subject | Performance | en_US |
dc.subject | Parameter | en_US |
dc.subject | Piping | en_US |
dc.subject | Geometry | en_US |
dc.title | Experimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outlet | en_US |