Experimental investigation of thermal performance of aluminum finned heat exchangers and open-cell aluminum foam heat exchangers
Küçük Resim Yok
Tarih
2012
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
ELSEVIER SCIENCE INC
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study six heat exchangers were experimentally investigated; three of them were aluminum foam heat exchangers and the other three were aluminum fin heat exchangers. The open cell aluminum foam heat exchangers were of PPI 10, 20, 30 features and dimensions of 200 x 200 x 100 mm. The aluminum fin heat exchangers were of the same dimensions as the open cell aluminum heat exchangers and with fin intervals of 1.6, 3.2, 4.8 mm. By using experimental data, variations of effectiveness versus velocity, pressure loss versus velocity, friction factor versus Reynolds number and Reynolds number versus Nusselt number have been investigated. The Reynolds number used in the tests was at around 5 x 10(3)-9 x 10(4). It was found that, for both types of heat exchangers, as the velocity of refrigerant increases, the effectiveness drops and pressure loss increases. The effectiveness was higher at lower Reynolds numbers. It was found that aluminum fin heat exchangers transfer much more heat than their aluminum foam counter parts. (C) 2011 Elsevier Inc. All rights reserved.
Açıklama
Anahtar Kelimeler
Aluminum foam, Aluminum finned, Heat exchanger, Porous medium
Kaynak
EXPERIMENTAL THERMAL AND FLUID SCIENCE
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
36