A Calix[4]arene-tren modified electrode for determination of Lead ions in aqueous solution

dc.contributor.authorKocer, Mustafa Baris
dc.contributor.authorErdogan, Zehra Ozden
dc.contributor.authorOguz, Mehmet
dc.contributor.authorKucukkolbasi, Semahat
dc.contributor.authorYilmaz, Mustafa
dc.date.accessioned2020-03-26T20:12:14Z
dc.date.available2020-03-26T20:12:14Z
dc.date.issued2019
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractIn this study, a simple and sensitive electrochemical sensor based on Calix[4]arene-tren (Calix-tren) modified glassy carbon (GC) electrode was developed for the determination of Pb (II) ions. Electrochemical behavior of Calix-tren modified electrodes were investigated by using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results indicate that Calix-tren modified GC electrode provides good electron transmission pathway than bare GC electrode. The amount of Pb (II) was determined by differential pulse anodic stripping voltammetric analysis as a sensitive detection technique. The experimental parameters such as pH, deposition time and deposition potential were optimized. The optimum pH value was selected as 7.0. The effect of deposition potential and deposition time on the peak current was tested and the optimum values were chosen as -1.2 V and 120 s, respectively. Under the optimal conditions, the working range of the developed sensor was determined as 0.48-2.31 mu M, limit of detection (LOD) was 0.11 mu M and the RSD obtained in the reproducibility study was 2.78 %. It was also found that the developed method could be used in the determination of Pb (II) ions in real samples with satisfactory results.en_US
dc.identifier.doi10.25135/acg.oc.65.19.07.1330en_US
dc.identifier.endpage168en_US
dc.identifier.issn1307-6175en_US
dc.identifier.issue3en_US
dc.identifier.pmid#YOKen_US
dc.identifier.scopusqualityQ4en_US
dc.identifier.startpage160en_US
dc.identifier.urihttps://dx.doi.org/10.25135/acg.oc.65.19.07.1330
dc.identifier.urihttps://hdl.handle.net/20.500.12395/37388
dc.identifier.volume12en_US
dc.identifier.wosWOS:000484346200006en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherACG PUBLICATIONSen_US
dc.relation.ispartofORGANIC COMMUNICATIONSen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectCalix[4]areneen_US
dc.subjectelectrochemical sensoren_US
dc.subjectPb (II)en_US
dc.titleA Calix[4]arene-tren modified electrode for determination of Lead ions in aqueous solutionen_US
dc.typeArticleen_US

Dosyalar