Experimental investigation of the effects of threefold type Ranque-Hilsch vortex tube and six cascade type Ranque-Hilsch vortex tube on the performance of counter flow Ranque-Hilsch vortex tubes

dc.contributor.authorDincer, Kevser
dc.date.accessioned2020-03-26T18:14:38Z
dc.date.available2020-03-26T18:14:38Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description23rd IIR International Congress of Refrigeration -- AUG 21-26, 2011 -- Prague, CZECH REPUBLICen_US
dc.description.abstractIn this study, performances of Ranque-Hilsh Vortex Tubes (RHVTs) were experimentally investigated under three different situations based on inlet pressure and the ratio of mass flow rate of the cold stream to the mass flow rate of the inlet stream (xi). 1st situation is the conventional RHVT. 2nd situation is the threefold cascade type RHVT. Here three RHVTs were used. 3rd situation deals with the six cascade type RHVT. In this case, six RHVTs were used. When all the test results under P-i = 360 kPa and P-i = 400 kPa pressure conditions are compared, it is found that the best performance occurs at the 3rd situation. Moreover, the performance of the 3rd situation at P-i = 400 kPa pressure is higher than that at P-i = 360 kPa. Maximum values of Delta T and xi are obtained as 67.6 degrees C and 0.9 for 3rd situation. (C) 2011 Elsevier Ltd and IIR. All rights reserved.en_US
dc.description.sponsorshipSelcuk UniversitySelcuk University [BAP 08401034]en_US
dc.description.sponsorshipFinancial support of this study by the research fund of the Selcuk University under grant No. BAP 08401034 is gratefully acknowledged.en_US
dc.identifier.doi10.1016/j.ijrefrig.2011.05.008en_US
dc.identifier.endpage1371en_US
dc.identifier.issn0140-7007en_US
dc.identifier.issn1879-2081en_US
dc.identifier.issue6en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage1366en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.ijrefrig.2011.05.008
dc.identifier.urihttps://hdl.handle.net/20.500.12395/26485
dc.identifier.volume34en_US
dc.identifier.wosWOS:000294398000006en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherELSEVIER SCI LTDen_US
dc.relation.ispartofINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROIDen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectVortex tubeen_US
dc.subjectRanque-Hilschen_US
dc.subjectExperimenten_US
dc.subjectGeometryen_US
dc.titleExperimental investigation of the effects of threefold type Ranque-Hilsch vortex tube and six cascade type Ranque-Hilsch vortex tube on the performance of counter flow Ranque-Hilsch vortex tubesen_US
dc.typeArticleen_US

Dosyalar