Experimental investigation of the effects of threefold type Ranque-Hilsch vortex tube and six cascade type Ranque-Hilsch vortex tube on the performance of counter flow Ranque-Hilsch vortex tubes
dc.contributor.author | Dincer, Kevser | |
dc.date.accessioned | 2020-03-26T18:14:38Z | |
dc.date.available | 2020-03-26T18:14:38Z | |
dc.date.issued | 2011 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description | 23rd IIR International Congress of Refrigeration -- AUG 21-26, 2011 -- Prague, CZECH REPUBLIC | en_US |
dc.description.abstract | In this study, performances of Ranque-Hilsh Vortex Tubes (RHVTs) were experimentally investigated under three different situations based on inlet pressure and the ratio of mass flow rate of the cold stream to the mass flow rate of the inlet stream (xi). 1st situation is the conventional RHVT. 2nd situation is the threefold cascade type RHVT. Here three RHVTs were used. 3rd situation deals with the six cascade type RHVT. In this case, six RHVTs were used. When all the test results under P-i = 360 kPa and P-i = 400 kPa pressure conditions are compared, it is found that the best performance occurs at the 3rd situation. Moreover, the performance of the 3rd situation at P-i = 400 kPa pressure is higher than that at P-i = 360 kPa. Maximum values of Delta T and xi are obtained as 67.6 degrees C and 0.9 for 3rd situation. (C) 2011 Elsevier Ltd and IIR. All rights reserved. | en_US |
dc.description.sponsorship | Selcuk UniversitySelcuk University [BAP 08401034] | en_US |
dc.description.sponsorship | Financial support of this study by the research fund of the Selcuk University under grant No. BAP 08401034 is gratefully acknowledged. | en_US |
dc.identifier.doi | 10.1016/j.ijrefrig.2011.05.008 | en_US |
dc.identifier.endpage | 1371 | en_US |
dc.identifier.issn | 0140-7007 | en_US |
dc.identifier.issn | 1879-2081 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 1366 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.ijrefrig.2011.05.008 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/26485 | |
dc.identifier.volume | 34 | en_US |
dc.identifier.wos | WOS:000294398000006 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER SCI LTD | en_US |
dc.relation.ispartof | INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Vortex tube | en_US |
dc.subject | Ranque-Hilsch | en_US |
dc.subject | Experiment | en_US |
dc.subject | Geometry | en_US |
dc.title | Experimental investigation of the effects of threefold type Ranque-Hilsch vortex tube and six cascade type Ranque-Hilsch vortex tube on the performance of counter flow Ranque-Hilsch vortex tubes | en_US |
dc.type | Article | en_US |