1,10-Phenanthroline modified glassy carbon electrode for voltammetric determination of cadmium(II) ions

Küçük Resim Yok

Tarih

2011

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER SCIENCE SA

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

This study reports the electrochemical modification of glassy carbon (GC) electrode surface with the electro-polymerized form of 1,10-phenanthroline monohydrate (PMH), the characterization of this polyphenanthroline modified electrode (PPMH/GC) and the electroanalytical application suitable for the determination of Cd(II) ions. The PPMH/GC electrode was characterized by cyclic voltammetry, chronoamperometry and atomic force microscopy and formation of polyphenanthroline layer grafted to surface of GC electrode was evidenced. Selectivity of PPMH/GC electrode towards heavy metal ions was investigated by square wave voltammetry. The PPMH/GC electrode was found to be suitable for selective determination of Cd(II) in the solutions containing the mixture of heavy metal ions and showed high stability and reproducibility. The analytical methodology was successfully applied for monitoring the toxic metal ions in real samples. (C) 2011 Elsevier B.V. All rights reserved.

Açıklama

Anahtar Kelimeler

Surface modification, Surface characterization, Glassy carbon electrode, Electrochemical sensors, Heavy metals, Cd(II) ion detection

Kaynak

SENSORS AND ACTUATORS B-CHEMICAL

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

157

Sayı

1

Künye