A Comparison of Bond Strengths of Soft Denture Liners to Polymethyl Methacrylate Polymerized by Conventional Water Bath and Microwave Curing Techniques

dc.contributor.authorİlbay, Sevcan Akesi
dc.contributor.authorİlbay, S. G.
dc.date.accessioned2020-03-26T16:24:20Z
dc.date.available2020-03-26T16:24:20Z
dc.date.issued1993
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractThis study compared the tensile bond strengths of soft lining materials polymerized by using conventional water bath methods and microwave energy. The soft lining materials used in this investigation were heat temperature vulcanizing (H.T.V.) silicon material Molloplast-B, and room temperature vulcanizing (R.T.V) acrylic material Getz Soft Oryl. The H.T.V. specimens were prepared with retention, additional retention and without retention, and the R.T.V. specimens were prepared by using bonding agent and bonding agent plus retention. All were cured by both conventional water bath and microwave energy. Results showed that the mean bond strength of H.T.V. specimens ranged from 9.6 to 13.12 kg/cm2, while the mean bond strength of R.T.V. specimens ranged from 0.36 to 1.75 kg/cm2. In both conventional and microwave groups, the specimens prepared with retention, additional retention and without retention or using bonding agent and bonding agent plus retention did not show any significant difference when they were compared separately. But the difference between conventional and microwave groups was found significant in both H.T.V. and R.T.V. specimens. It showed that conventional water bath technique is better than microwave technique.en_US
dc.identifier.citationAkesi-İlbay, S., İlbay, S. G., (1993). A Comparison of Bond Strengths of Soft Denture Liners to Polymethyl Methacrylate Polymerized by Conventional Water Bath and Microwave Curing Techniques. Journal of Marmara University Dental Faculty, 1(4), 327-332.
dc.identifier.endpage332en_US
dc.identifier.issn1018-5992en_US
dc.identifier.issue4en_US
dc.identifier.pmid9582635en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage327en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/16179
dc.identifier.volume1en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorAkesi-İlbay, S.
dc.institutionauthorİlbay, S. G.
dc.language.isoenen_US
dc.relation.ispartofJournal of Marmara University Dental Facultyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleA Comparison of Bond Strengths of Soft Denture Liners to Polymethyl Methacrylate Polymerized by Conventional Water Bath and Microwave Curing Techniquesen_US
dc.typeArticleen_US

Dosyalar