Microtensile bond strength of a filled vs unfilled adhesive to dentin using self-etch and total-etch technique
dc.contributor.author | Say, EC | |
dc.contributor.author | Nakajima, M | |
dc.contributor.author | Senawongse, P | |
dc.contributor.author | Soyman, M | |
dc.contributor.author | Ozer, F | |
dc.contributor.author | Ogata, M | |
dc.contributor.author | Tagami, J | |
dc.date.accessioned | 2020-03-26T17:03:55Z | |
dc.date.available | 2020-03-26T17:03:55Z | |
dc.date.issued | 2006 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | Objective: The purpose of this study was to evaluate the effect of a filled adhesive (One-Step Plus; Bisco) versus an unfilled adhesive (One-Step; Bisco) on the microtensite bond strength (mu TBS) to dentin using total-etch (Uni-etch; Bisco) and self-etch (Tyrian SPE; Bisco) techniques. Methods: Twenty extracted human third molars were ground flat to expose occlusal dentin. After the dentin surfaces were polished with 600-grit SiC paper, the teeth were randomly assigned to four groups according to the bonding agent and technique being used. Dentin surfaces were bonded with One-Step Plus + total-etch; One-Step Plus+self-etch; One- Step+ total-etch and One-Step + self-etch. Composite buildups were performed with Clearfil AP-X (Kuraray Medical). Following storage in distilled water at 37 degrees C for 24 h, the bonded specimens were serially sectioned into 0.7 mm-thick stabs and then trimmed to hour-glass shapes with a 1 mm? cross-sectional area (n = 20). Microtensile bond strengths were determined using the EZ-test (Shimadzu) at a cross-head speed of 1 mm/min. Data were analyzed using two-way ANOVA and Tukey's post hoc test. Results: There were no significant differences in the mu TBS between One-Step Plus and One-Step adhesives when they were used with the total-etch and self-etch techniques (p > 0.05). However with the total-etch technique both adhesives yielded significantly higher bond strength values than the self-etch technique (p < 0.001). Conclusion: The fitted adhesive One-Step Plus did not show any beneficial effect than the unfilled adhesive One-Step on the mu TBS to dentin with total-etch and self-etch techniques. Irrespective from the adhesive type, self-etch technique revealed lower bond strengths than the total-etch technique. (c) 2005 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi | 10.1016/j.jdent.2005.07.003 | en_US |
dc.identifier.endpage | 291 | en_US |
dc.identifier.issn | 0300-5712 | en_US |
dc.identifier.issn | 1879-176X | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.pmid | 16214284 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 283 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.jdent.2005.07.003 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/20586 | |
dc.identifier.volume | 34 | en_US |
dc.identifier.wos | WOS:000236927800004 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER SCI LTD | en_US |
dc.relation.ispartof | JOURNAL OF DENTISTRY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | filled adhesive | en_US |
dc.subject | unfilled adhesive | en_US |
dc.subject | total-etch | en_US |
dc.subject | self-etch | en_US |
dc.title | Microtensile bond strength of a filled vs unfilled adhesive to dentin using self-etch and total-etch technique | en_US |
dc.type | Article | en_US |