Cytotoxicity evaluation of luting resin cements on bovine dental pulp-derived cells (bDPCs) by real-time cell analysis

Küçük Resim Yok

Tarih

2015

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

JAPANESE SOC DENTAL MATERIALS DEVICES

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

To evaluate the cytotoxicity of resin cements on dental pulp-derived cells (bDPCs), Bifix QM (BQM), Choice 2(C2), RelyX U200(RU200), Maxcem Elite(ME), and Multilink Automix(MA) were tested. The materials were incubated in DMEM for 72 h. A real-time cell analyzer was used to evaluate cell survival. The statistical analyses used were one-way ANOVA and Tukey-Kramer tests. BQM, RU200, and ME demonstrated a significant decrease in the bDPCs' index at 24 and 72 h (p <= 0.001). These materials were found to be the most toxic resin cements, as compared to the control and other tested materials (C2 and MA). However, C2 and MA showed a better survival rate, compared to BQM, RU200, and ME, and had lower cell index than the control group. The cytotoxic effects of resin cements on pulpa should be evaluated during the selection of proper cements.

Açıklama

Anahtar Kelimeler

Cytotoxicity, Resin cements, Real-time cell analysis, Dental pulp-derived cells

Kaynak

DENTAL MATERIALS JOURNAL

WoS Q Değeri

Q3

Scopus Q Değeri

Q1

Cilt

34

Sayı

2

Künye