Failure Analysis of (+/- 55 Degrees)(3) Filament Wound Composite Pipes With an Inclined Surface Crack Under Static Internal Pressure
Yükleniyor...
Dosyalar
Tarih
2010
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier Sci Ltd
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
This study conducts failure analysis of filament wound glass reinforced plastic (GRP) pipes made of E-glass/epoxy with an inclined surface crack under open-ended internal pressure. Test specimens are composed of six antisymmetric layers with (+/- 55 degrees)(3) winding angles. Tests have been performed at seven different crack angles: 0 degrees, 15 degrees, 30 degrees, 60 degrees, 45 degrees, 75 degrees, and 90 degrees, with crack-to-thickness ratio of a/t = 0.50. The burst strengths of the specimens were determined, and the dependence of the burst strength on the crack angle was examined.
Açıklama
Anahtar Kelimeler
GRP pipe, Inclined surface crack, Burst strength, Internal pressure
Kaynak
Composite Structures
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
92
Sayı
Künye
Arıkan, H., (2010). Failure Analysis of (+/- 55 Degrees)(3) Filament Wound Composite Pipes With an Inclined Surface Crack Under Static Internal Pressure. Composite Structures, (92), 182-187. Doi: 10.1016/j.compstruct.2009.07.027