Failure Analysis of (+/- 55 Degrees)(3) Filament Wound Composite Pipes With an Inclined Surface Crack Under Static Internal Pressure
dc.contributor.author | Arıkan, Hüseyin | |
dc.date.accessioned | 2020-03-26T17:48:44Z | |
dc.date.available | 2020-03-26T17:48:44Z | |
dc.date.issued | 2010 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | This study conducts failure analysis of filament wound glass reinforced plastic (GRP) pipes made of E-glass/epoxy with an inclined surface crack under open-ended internal pressure. Test specimens are composed of six antisymmetric layers with (+/- 55 degrees)(3) winding angles. Tests have been performed at seven different crack angles: 0 degrees, 15 degrees, 30 degrees, 60 degrees, 45 degrees, 75 degrees, and 90 degrees, with crack-to-thickness ratio of a/t = 0.50. The burst strengths of the specimens were determined, and the dependence of the burst strength on the crack angle was examined. | en_US |
dc.description.sponsorship | Selcuk UniversitySelcuk University | en_US |
dc.description.sponsorship | This work was supported by the Coordination of Scientific Research at Selcuk University. | en_US |
dc.identifier.citation | Arıkan, H., (2010). Failure Analysis of (+/- 55 Degrees)(3) Filament Wound Composite Pipes With an Inclined Surface Crack Under Static Internal Pressure. Composite Structures, (92), 182-187. Doi: 10.1016/j.compstruct.2009.07.027 | |
dc.identifier.doi | 10.1016/j.compstruct.2009.07.027 | en_US |
dc.identifier.endpage | 187 | en_US |
dc.identifier.issn | 0263-8223 | en_US |
dc.identifier.issn | 1879-1085 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 182 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.compstruct.2009.07.027 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/24931 | |
dc.identifier.volume | 92 | en_US |
dc.identifier.wos | WOS:000271563100020 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.institutionauthor | Arıkan, Hüseyin | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Sci Ltd | en_US |
dc.relation.ispartof | Composite Structures | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | GRP pipe | en_US |
dc.subject | Inclined surface crack | en_US |
dc.subject | Burst strength | en_US |
dc.subject | Internal pressure | en_US |
dc.title | Failure Analysis of (+/- 55 Degrees)(3) Filament Wound Composite Pipes With an Inclined Surface Crack Under Static Internal Pressure | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 4931.pdf
- Boyut:
- 544.29 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası