Immediate mechanical stability of sagittal split ramus osteotomy fixed with resorbable compared with titanium bicortical screws in mandibles of sheep

dc.contributor.authorCilasun, Ulkem
dc.contributor.authorUckan, Sina
dc.contributor.authorDolanmaz, Dogan
dc.contributor.authorSaglam, Haci
dc.date.accessioned2020-03-26T17:03:42Z
dc.date.available2020-03-26T17:03:42Z
dc.date.issued2006
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractTen fresh mandibles from adult sheep were stripped of all soft tissues and sectioned in the midline. We did sagittal split osteotomies and 5 mm advancement on all the 20 hemimandibles. Ten hemimandibles were fixed with three 2.0 mm x 13 mm titanium bicortical screws, and the other 10 were fixed with three 2.0 mm x 13 MM poly-L-lactic acid/polyglycolic acid (PLLA/PGA) bicortical screws in an inverted L pattern. All the hemimandibles were then mounted in a servohydraulic testing unit and tested to permanent deformation. Maximum forces that the mandibles resisted before breaking, maximum displacements, and the displacement values under 20, 60, 120, and 150N were compared using the Mann-Whitney U-test. There were no significant differences in stability between the bones fixed with titanium and those fixed with resorbable screws. (C) 2005 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.bjoms.2005.11.020en_US
dc.identifier.endpage537en_US
dc.identifier.issn0266-4356en_US
dc.identifier.issue6en_US
dc.identifier.pmid16423434en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage534en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.bjoms.2005.11.020
dc.identifier.urihttps://hdl.handle.net/20.500.12395/20531
dc.identifier.volume44en_US
dc.identifier.wosWOS:000242554400017en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherCHURCHILL LIVINGSTONEen_US
dc.relation.ispartofBRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectorthognathic surgeryen_US
dc.subjectPLLA/PGAen_US
dc.subjecttensionen_US
dc.subjectstabilityen_US
dc.subjectpositional screwen_US
dc.subjecttitaniumen_US
dc.titleImmediate mechanical stability of sagittal split ramus osteotomy fixed with resorbable compared with titanium bicortical screws in mandibles of sheepen_US
dc.typeArticleen_US

Dosyalar