Adeziv Sistemlerin ve Kompozit Rezin Materyallerin Derin Dentine Bağlanma Dayanımlarının İncelenmesi: in vitro çalışma

dc.authorid0000-0002-9161-9524en_US
dc.authorid0000-0002-2675-1764en_US
dc.authorid0000-0001-5708-1030en_US
dc.contributor.authorGürses, Merve
dc.contributor.authorTağtekin, Dilek
dc.contributor.authorYanikoglu, Funda
dc.date.accessioned2023-01-11T13:15:45Z
dc.date.available2023-01-11T13:15:45Z
dc.date.issued2021en_US
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractAmaç: Bu çalışmanın amacı, düz dentin yüzeylerinde 2 farklı adeziv sistemin ve 3 farklı kompozit rezinin dentine mikrogerilim bağlanma kuvvetinin (µTBS) belirlenmesi ve bağlanma dayanımı üzerine etkisinin incelenmesidir. Gereç ve Yöntemler: 24 adet insan 3. büyük azı dişinde düz derin dentin yüzeyleri hazırlanmıştır. Dişler rastgele seçilerek, Self-etch (Futurabond M SingleDose VOCO) ve Total-etch (% 37 fosforik asit Condac 37, Adeziv 200T 3M) uygulananlar olarak iki gruba ayrılmıştır. Gruplar 3’er alt gruba ayrılmak üzere, 3 farklı kompozit rezin (X-tra Fill VOCO, SonicFill Kerr, Grandio VOCO) uygulanarak restore edilmiştir. Tüm dişlerin merkezinden 6’şar adet çubuk şeklinde numune elde edilmiştir. Tüm numunelere mikrogerilim testi uygulanmıştır. İstatistiksel analiz testleri Sigmaplot 12.5 paket programında gerçekleştirilmiştir. KruskalWallis ve Tukey testleri kullanılmıştır. Bulgular: Grupların median değerleri arasında istatistiksel olarak anlamlı bir farklılık olduğu görülmüştür (p=0.01). Tukey testinin sonuçlarına göre (p<0.05); Adeziv 200T 3M grubunda, Grandio VOCO (inkremental) kompozit ile X-tra Fill VOCO (bulk) kompozit (p=0.008) ve SonicFill Kerr (bulk) kompozit rezinin (p=0.022) bağlanma dayanımı verileri arasındaki farklılık istatistiksel olarak anlamlı bulunmuştur. Futurabond M SingleDose grubunda ise kompozitlerin bağlanma dayanımı verileri arasında istatistiksel olarak anlamlı bir farklılık görülmemiştir (p>0.05). Sonuç: Dentine bağlanma dayanımlarında adeziv sistemler arasında fark görülmezken; geleneksel inkremental kompozit, bulk-fill kompozitlerden daha başarılı bulunmuştur.en_US
dc.description.abstractBackground: The aim of this study is to determine the microtensile bond strength (µTBS) of two different adhesive systems and three different composite resins to dentin and to investigate the their effects on bond strength. Methods: This study was performed on 24 third molar teeth. Teeth are randomly selected and divided into two groups, Selfetch (Futurabond M SingleDose VOCO) and Total-etch (% 37 phosphoric acide Condac 37, Adeziv 200T 3M). Each gruop was divided into three sub-groups based on composite types (X-tra Fill VOCO, SonicFill Kerr, Grandio VOCO). 6 rods were obtained from the center of each tooth. µTBS test was applied to all samples and data was collected. Statistical analysis was performed in Sigmaplot 12.5 software. Kruskal-Wallis and Tukey tests were used. Results: There was a statistically significant difference between the median values of the groups (p=0.01). According to the results of the Tukey test (p <0.05); in the Adhesive 200T 3M group, the difference between microtensile bond strength data of Grandio VOCO (incremental) composite and X-tra Fill VOCO (bulk) composite (p = 0.008) and SonicFill Kerr (bulk) composite resin (p = 0.022) was statistically significant. In the Futurabond M SingleDose group, there was no statistically significant difference between the microtensile bond strength data of composites (p> 0.05). Conclusion: There was no difference in adhesive bonding strength between adhesive systems; conventional incremental composite was found to be more successful than Bulk-fill composites.en_US
dc.identifier.citationGürses, M., Tağtekin, D., Yanikoglu, F., (2021). Adeziv Sistemlerin ve Kompozit Rezin Materyallerin Derin Dentine Bağlanma Dayanımlarının İncelenmesi: in vitro çalışma. Selçuk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 8 (2), 500-507. Doi: 10.15311/selcukdentj.770722en_US
dc.identifier.doi10.15311/selcukdentj.770722en_US
dc.identifier.endpage507en_US
dc.identifier.issn2148-7529en_US
dc.identifier.issue2en_US
dc.identifier.startpage500en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/44276
dc.identifier.volume8en_US
dc.institutionauthorGürses, Merve
dc.language.isotren_US
dc.publisherSelçuk Üniversitesien_US
dc.relation.ispartofSelçuk Üniversitesi Diş Hekimliği Fakültesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectAdeziv sistemen_US
dc.subjectBulk fillen_US
dc.subjectKompozit rezinen_US
dc.subjectMikrogerilimen_US
dc.subjectAdhesive systemen_US
dc.subjectMicrotensileen_US
dc.subjectResin compositeen_US
dc.titleAdeziv Sistemlerin ve Kompozit Rezin Materyallerin Derin Dentine Bağlanma Dayanımlarının İncelenmesi: in vitro çalışmaen_US
dc.title.alternativeEvaluation of Bonding Strength of Adhesive Systems and Composite Resins to Deep Dentin Surfaces: in vitro studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
19.pdf
Boyut:
805.95 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: