Determination of Ochratoxin A in Poultry Feed by High-Performance Liquid Chromatography with a Monolithic Column
dc.contributor.author | Shar, Zahid Hussain | |
dc.contributor.author | Sumbal, Gul Ameer | |
dc.contributor.author | Sherazi, Syed Tufail Hussain | |
dc.contributor.author | Kara, Huseyin | |
dc.contributor.author | Hussain, Masood | |
dc.contributor.author | Bhanger, Muhammad Iqbal | |
dc.date.accessioned | 2020-03-26T19:01:47Z | |
dc.date.available | 2020-03-26T19:01:47Z | |
dc.date.issued | 2015 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | A monolithic column with high-performance liquid chromatography coupled with an ultraviolet detector was investigated for the determination of ochratoxin A in poultry feed. A systematic study was performed using solid phase extraction with a C-18 cartridge for sample pretreatment with three solvent systems. Ethyl acetate:methanol:formic acid (95:5:0.5) was found to be the most suitable. Pretreated samples were injected separately into packed and monolithic columns. The effects of the mobile phases on the chromatographic figures of merits were evaluated. Better peak symmetry, improved separation, and more theoretical plates were observed using an acetonitrile:water:formic acid (99:99:2) mobile phase. The repeatability and accuracy of the method were statistically evaluated and found to be satisfactory with a limit of detection of 40 mu gL(-1). The use of a monolithic column in conjunction with sample pretreatment provided good results for the determination of ochratoxin A in poultry feed. | en_US |
dc.description.sponsorship | Higher Education Commission (HEC), PakistanHigher Education Commission of Pakistan [20-1544/RD/09/2204]; TUBITAKTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) | en_US |
dc.description.sponsorship | The authors would like to acknowledge the Higher Education Commission (HEC), Pakistan, with great thanks for providing the financial support to carry out this research work under project No. 20-1544/R&D/09/2204. The authors would also like to thank TUBITAK for providing financial support to Professor Dr. S. T. H. Sherazi under the TUBITAK 2221 Fellowship for Visiting Scientists and Scientists on Sabbatical Leave program. | en_US |
dc.identifier.doi | 10.1080/00032719.2014.951447 | en_US |
dc.identifier.endpage | 407 | en_US |
dc.identifier.issn | 0003-2719 | en_US |
dc.identifier.issn | 1532-236X | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.startpage | 396 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1080/00032719.2014.951447 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/31996 | |
dc.identifier.volume | 48 | en_US |
dc.identifier.wos | WOS:000345504500002 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | TAYLOR & FRANCIS INC | en_US |
dc.relation.ispartof | ANALYTICAL LETTERS | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Monolithic column | en_US |
dc.subject | Poultry feed | en_US |
dc.subject | Ochratoxin A | en_US |
dc.subject | High-performance liquid chromatography | en_US |
dc.subject | Ultraviolet detector | en_US |
dc.title | Determination of Ochratoxin A in Poultry Feed by High-Performance Liquid Chromatography with a Monolithic Column | en_US |