dc.description.abstractPurpose: To evaluate the effect of pupil dilation on the biometric parameters of the Lenstar LS 900 (Haag Streit AG, Koeniz, Switzerland). Methods: In this cross-sectional study of 33 eyes with cataracts, axial length (AL), anterior chamber depth, intraocular lens (IOL) power, keratometry, and pupil diameter measurements were performed using Lenstar biometry before and after pupil dilatation. Intraobserver repeatability was assessed by taking 2 consecutive recordings of biometric parameters using Lenstar biometry in the undilated pupils of 30 eyes with cataracts. Results: The mean difference in AL measurements from intraobserver readings was -0.001 +/- 0.01 mm. The study group showed a statistically significant change in the first keratometry reading and anterior chamber depth values (P < 0.05); however, the mean difference in AL and IOL power was statistically insignificant between the undilated and dilated pupil Lenstar biometry readings. Three cases in the study group (9.1%) and 1 case in the control group (3.3%) demonstrated changes in IOL power >0.50 diopter. Conclusions: Dilated and undilated pupil size did not affect the measurement of IOL using the Lenstar biometry.en_US
dc.description.sponsorshipScientific Research Coordination Center of Selcuk UniversitySelcuk University [BAP-11701453]en_US
dc.description.sponsorshipSupported by the Scientific Research Coordination Center of Selcuk University (BAP-11701453).en_US
dc.identifier.doi10.1097/ICO.0b013e31825fee82en_US
dc.identifier.endpageE24en_US
dc.identifier.issn0277-3740en_US
dc.identifier.issn1536-4798en_US
dc.identifier.issue4en_US
dc.identifier.pmid23023403en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpageE21en_US
dc.identifier.urihttps://dx.doi.org/10.1097/ICO.0b013e31825fee82
dc.identifier.urihttps://hdl.handle.net/20.500.12395/29913
dc.identifier.volume32en_US
dc.identifier.wosWOS:000315999500005en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherLIPPINCOTT WILLIAMS & WILKINSen_US
dc.relation.ispartofCORNEAen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectaxial lengthen_US
dc.subjectinterferometryen_US
dc.subjectLenstaren_US
dc.subjectocular biometryen_US
dc.subjectpupil dilationen_US
dc.titleThe Effect of Pupil Dilation on Biometric Parameters of the Lenstar 900en_US
dc.typeArticleen_US

Dosyalar