Objectives: Persistent or transient hearing loss (HL) is a less-recognized complication of spinal anesthesia (SA) in the pediatric population, although it has been previously reported in adults. The primary aim of this study was to investigate the effects of SA on auditory function in the pediatric population. Methods: After gaining institutional approval and parental consent, 30 American Society of Anesthesiologists physical status I-II children between 4 and 15 years undergoing lower extremity orthopedic surgery were enrolled in this prospective study. Spinal blocks were performed in the midline with a 25G Quincke needle using 0.5% hyperbaric bupivacaine. Transient evoked otoacoustic emission (TEOAE) and distortion product otoacoustic emission (DPOAE) tests were administered before surgery and one-day postoperative. Children with detected HL were retested on postoperative day seven. Preoperative and postoperative results were compared. A Wilcoxin Signed-Ranks test (with Bonferroni correction) was used for statistical analyses. Results: There was no statistically significant HL in the postoperative period compared to the preoperative period. In 29 of 30 patients, no difference was detected at any frequency tested. In one patient, TEOAE and DPOAE tests were found to be decreased on postoperative day one. In this patient, control tests were found to be improved on postoperative day seven. Conclusions: Administration of SA may results in a low probability of transient hearing loss with no clinical significance in children 4-15 years of age. (C) 2016 Elsevier Ireland Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

Child, Hearing loss, Spinal anesthesia, Otoacoustic emissions

Kaynak

INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY

WoS Q Değeri

Q3

Scopus Q Değeri

Q2

Cilt

88

Sayı

Künye