Short-Term Outcomes of Patent Ductus Arteriosus Closure With New Occlutech (R) Duct Occluder: A Multicenter Study

dc.contributor.authorDedeoğlu, Reyhan
dc.contributor.authorBilici, Meki
dc.contributor.authorDemir, Fikri
dc.contributor.authorDemir, Fadli
dc.contributor.authorAcar, Onur Cağlar
dc.contributor.authorHallioğlu, Olgu
dc.contributor.authorPaç, Ayşenur
dc.date.accessioned2020-03-26T19:26:21Z
dc.date.available2020-03-26T19:26:21Z
dc.date.issued2016
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractAim: Over the past 2 decades, transcatheter occlusion of patent ductus arteriosus (PDA) with coils and the duct occluders evolved to be the procedure of choice. A new device, the Occlutech PDA1 occluder (ODO) device has been designed. Herein, we aimed to evaluate the characteristics and short-term results of patients who underwent transcatheter closure of PDA using the ODO. Methods: We reviewed the clinical records of 60 patients from different centers in Turkey between December 2013 and January 2016. The medical records were reviewed for demographic characteristics and echocardiographic findings. Device size was selected on the narrowest diameter of PDA. Results: The median patient age was 2.5 years (6 months-35 years), and median PDA diameter was 2.5mm (1.2-11 mm). Fifty-eight of 60 patients (96.6%) had successful ODO implantation. The occlusion rates were 37/58 (63.7%) at the end of the procedure, 51/58 (87.9%) at 24-48 hours post-procedure, and 57/58 (98.2%) on echocardiography at a median follow-up of 7.6 months. Conclusion: Our results indicate that transcatheter closure of PDA using the ODO is effective. Larger studies and longer follow-up are required to assess whether its shape and longer length make it superior to other duct occluders in large, tubular, or window-type ducts.en_US
dc.identifier.doi10.1111/joic.12290en_US
dc.identifier.endpage331en_US
dc.identifier.issn0896-4327en_US
dc.identifier.issn1540-8183en_US
dc.identifier.issue3en_US
dc.identifier.pmid27090770en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage325en_US
dc.identifier.urihttps://dx.doi.org/10.1111/joic.12290
dc.identifier.urihttps://hdl.handle.net/20.500.12395/33993
dc.identifier.volume29en_US
dc.identifier.wosWOS:000384919800011en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWILEY-BLACKWELLen_US
dc.relation.ispartofJOURNAL OF INTERVENTIONAL CARDIOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleShort-Term Outcomes of Patent Ductus Arteriosus Closure With New Occlutech (R) Duct Occluder: A Multicenter Studyen_US
dc.typeArticleen_US

Dosyalar