Evaluation of Some Redox Mediators in the Design of Reagentless Amperometric Glucose Biosensor

dc.contributor.authorKausaite-Minkstimiene, Asta
dc.contributor.authorMazeiko, Viktor
dc.contributor.authorRamanaviciene, Almira
dc.contributor.authorOztekin, Yasemin
dc.contributor.authorSolak, Ali Osman
dc.contributor.authorRamanavicius, Arunas
dc.date.accessioned2020-03-26T18:50:37Z
dc.date.available2020-03-26T18:50:37Z
dc.date.issued2014
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractThe influence of redox mediators (tetrathiafulvalene (TTF), tetrathiafulvalene-tetracyanoquinodimethane complex (TTF-TCNQ), phenazine methosulfate (PMS), 5,6-diamino-1,10-phenonthroline (5,6-DAP), potassium ferrocyanide (K4[Fe(CN)6]), methylene blue (MB) and toluidine blue (TB)) on the response of amperometric glucose biosensor was investigated in this research. Graphite rod electrode (GRE) modified by adsorbed mediator and glucose oxidase (GOx) cross-linked with glutaraldehyde was served as working electrode. The highest amperometric signals were observed by using TTF and TTF-TCNQ as mediators. The impact of amount of immobilized GOx, an optimal pH region for operation, stability and reproducibility of the analytic signal of designed biosensor using these mediators were investigated and discussed.en_US
dc.description.sponsorshipResearch Council of Lithuania [TAP LB 09/2013]en_US
dc.description.sponsorshipThis research was funded by a grant (No. TAP LB 09/2013) from the Research Council of Lithuania. This support is gratefully acknowledged.en_US
dc.identifier.doi10.1002/elan.201400023en_US
dc.identifier.endpage1535en_US
dc.identifier.issn1040-0397en_US
dc.identifier.issn1521-4109en_US
dc.identifier.issue7en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1528en_US
dc.identifier.urihttps://dx.doi.org/10.1002/elan.201400023
dc.identifier.urihttps://hdl.handle.net/20.500.12395/30843
dc.identifier.volume26en_US
dc.identifier.wosWOS:000339483200013en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherWILEY-V C H VERLAG GMBHen_US
dc.relation.ispartofELECTROANALYSISen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectAmperometric glucose biosensoren_US
dc.subjectImmobilized glucose oxidaseen_US
dc.subjectElectron transfer mediatoren_US
dc.subjectMethylene blueen_US
dc.subjectToluidine blueen_US
dc.titleEvaluation of Some Redox Mediators in the Design of Reagentless Amperometric Glucose Biosensoren_US
dc.typeArticleen_US

Dosyalar