Depth of cure and microhardness of a new composite vs. bulk-fill composites

dc.contributor.authorCetin, Ali Riza.
dc.contributor.authorHataysal, Ahmet Ercan.
dc.contributor.authorKaplan, Taibe Tokgoz.
dc.contributor.authorBotsali, Murat Selim.
dc.date.accessioned2020-03-26T20:13:15Z
dc.date.available2020-03-26T20:13:15Z
dc.date.issued2019
dc.departmentSelçuk Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractAim: To compare the depth of cure of new composite with bulk fill resin composites through using Vickers hardness profiles (VHN). Materials and Methods: New composite and four bulk fill composite materials were examined: Tetric N Ceram (R) Bulk Fill, X-tra base, Compon, Filtek Posterior Bulk Fill, Sonic FiIITM. Eight specimens of each material type were prepared in teflon molds which contained a slot of dimensions (8 mm x 4 mm x 2 mm), and a top plate. The molds were irradiated from one end. All specimens were stored at 37 degrees C for 24 h, before measurement. The Vickers hardness was measured as a function of depth of material, at 1 mm intervals. Data were analyzed by one-way ANOVA using Turkey post hoc tests (p=0.05). Results: The maximum VHN ranged from 46.7 to 68.1, whilst the 80% of max. WIN ranged from 374 to 54.5. The depth corresponding to 80% of maximum VHN ranged from 5.5 to 7 mm. This was taken as the depth-of cure. Discussion: In this study, VHN, 80% VHN and depth profile properties of different Bulk Fill resin composites were measured and compared with the new composite by the determination of their VHN/depth profiles. There were statistically significant differences between different bulk fill composite materials in terms of max. VHN and depth of cure, corresponding to 80% of max. VHN. Depth of cure is related to the clinical success of restoration. When a more extensive polymerization and crosslinking occurs,greater VHN results are obtained. According to the manufacturer's claims bulk fill composites can be applied up to 4 mm, or even 5 mm in one time. In general, adequate polymerization along the recommended depth in bulk fill composites is critical to the long-term stability of restorations. According to the results of our research, the manufacturers' claim was approved for these materials. Conclusion: New composite can be cured to an acceptable post-cure depth as Bulk fill resin composites, according to the manufacturers' claims. X-tra base had the greatest depth of cure among the composites examined.en_US
dc.identifier.citationCetin, A. R., Hataysal, A. E., Kaplan, T. T., Botsali, M. S. (2019). Depth of Cure and Microhardness of a New Composite vs. Bulk-fill Composites. Journal of Research in Medical and Dental Science, 7(5), 53-59.
dc.identifier.endpage59en_US
dc.identifier.issn2347-2545en_US
dc.identifier.issn2347-2367en_US
dc.identifier.issue5en_US
dc.identifier.pmid#YOKen_US
dc.identifier.startpage53en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/37654
dc.identifier.volume7en_US
dc.identifier.wosWOS:000497956500010en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.institutionauthorCetin, Ali Riza.
dc.institutionauthorHataysal, Ahmet Ercan.
dc.institutionauthorKaplan, Taibe Tokgoz.
dc.institutionauthorBotsali, Murat Selim.
dc.language.isoenen_US
dc.publisherAMBER PUBLICATIONen_US
dc.relation.ispartofJOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCEen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectBulk fill compositesen_US
dc.subjectMicrohardnessen_US
dc.subjectDepth of cureen_US
dc.titleDepth of cure and microhardness of a new composite vs. bulk-fill compositesen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Ali Rıza ÇETİN.pdf
Boyut:
462.99 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Full Text Access