Comparison of stability of titanium and absorbable plate and screw fixation for mandibular angle fractures

dc.contributor.authorEsen, Alparslan
dc.contributor.authorAtaoglu, Hanife
dc.contributor.authorGemi, Lokman
dc.date.accessioned2020-03-26T17:26:33Z
dc.date.available2020-03-26T17:26:33Z
dc.date.issued2008
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractObjective. The purpose of this experimental study was to compare the stability of titanium and absorbable plate and screw fixation systems for mandibular angle fractures. Study design. Twenty-one sheep hemimandibles were used to evaluate 3 different plating techniques. The groups were fixated with a single titanium plate, a single absorbable plate and double absorbable plates. A cantilever bending biomechanical test model was used for the samples. Each group was tested with vertical forces by a servohydraulic testing unit. The displacement values in each group at each 10 N stage up to 100 N were compared using the 2-way analysis of variance test. Results. The displacement values for the 3 groups differed significantly (P < .05). The variance analyses showed that titanium plate placement had more favorable biomechanical behavior than others. In addition, the 2 absorbable plates group had more favorable biomechanical behavior than a single absorbable plate group but it was not significantly different at 10 to 40 N. Conclusion. The study demonstrated that titanium plate and screw fixation system had greater resistance to occlusal loads than absorbable plate and screw systems. In addition, a second absorbable plate orientation provides a more favorable biomechanical behavior than a single absorbable plate placement. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 806-811)en_US
dc.identifier.doi10.1016/j.tripleo.2008.05.034en_US
dc.identifier.endpage811en_US
dc.identifier.issn1079-2104en_US
dc.identifier.issn1528-395Xen_US
dc.identifier.issue6en_US
dc.identifier.pmid18718777en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage806en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.tripleo.2008.05.034
dc.identifier.urihttps://hdl.handle.net/20.500.12395/22276
dc.identifier.volume106en_US
dc.identifier.wosWOS:000260758000005en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherMOSBY-ELSEVIERen_US
dc.relation.ispartofORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleComparison of stability of titanium and absorbable plate and screw fixation for mandibular angle fracturesen_US
dc.typeArticleen_US

Dosyalar