The precision of the panoramic mandibular index

dc.contributor.authorGüngör, K.
dc.contributor.authorAkarslan, Z. Z.
dc.contributor.authorAkdevelioğlu, M.
dc.contributor.authorErten, H.
dc.contributor.authorSemiz, M.
dc.date.accessioned2020-03-26T17:04:36Z
dc.date.available2020-03-26T17:04:36Z
dc.date.issued2006
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractObjectives: This study evaluates the precision of the panoramic mandibular index (PMI). Materials and methods: Measurements were made by two observers on both of the left and right sides of the mandible on the radiographs taken from 41. young individuals and the inferior and superior PMI were calculated. Two weeks later the same observers repeated their measurements to assess intrarater reliability. Paired t-test, Pearson correlation coefficients and precision values were calculated to assess levels of association. Results: There was a significant difference between the first rater's first and second measurements (intrarater repeatability) for both the inferior and superior PMI, while no significant difference was observed for the second rater. The intrarater and inter-rater precision values for the inferior PMI were calculated as 0.005319 and 0.005594 for the first rater and 0.005663 and 0.005594 for the second, respectively. The intrarater and inter-rater precision values for the superior PMI were similar for both observers, calculated as 0.002558, 0.002766; and 0.003046, 0.002766, respectively. The precision of both inferior and superior indices was not very good, but precision figures for the superior PMI demonstrated consistency almost twice better than those for the inferior PMI for both observers. Conclusions: The precision values for the PMI seem to be sufficient according to the results of this study, but they are still questionable and more studies need to be done on this aspect.en_US
dc.identifier.doi10.1259/dmfr/25346328en_US
dc.identifier.endpage446en_US
dc.identifier.issn0250-832Xen_US
dc.identifier.issn1476-542Xen_US
dc.identifier.issue6en_US
dc.identifier.pmid17082336en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage442en_US
dc.identifier.urihttps://dx.doi.org/10.1259/dmfr/25346328
dc.identifier.urihttps://hdl.handle.net/20.500.12395/20736
dc.identifier.volume35en_US
dc.identifier.wosWOS:000242714200009en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherBRITISH INST RADIOLOGYen_US
dc.relation.ispartofDENTOMAXILLOFACIAL RADIOLOGYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectpanoramicen_US
dc.subjectradiographyen_US
dc.subjectosteoporosisen_US
dc.subjectmandibleen_US
dc.titleThe precision of the panoramic mandibular indexen_US
dc.typeArticleen_US

Dosyalar