Vena cubiti media for creation of a loop-shaped arteriovenous fistula at the elbow region

dc.contributor.authorGormus, N
dc.contributor.authorOzergin, U
dc.contributor.authorOzpinar, C
dc.contributor.authorSolak, H
dc.date.accessioned2020-03-26T16:55:38Z
dc.date.available2020-03-26T16:55:38Z
dc.date.issued2004
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractHemodialysis access is one of the major routes, for patients who need long-term hemodialysis. In this report, we tried a new secondary arteriovenous fistula technique. Between January 2000 and June 2003, hemodialysis access was created in more than 650 patients with end-stage renal failure at our institution. In 15 cases a loop-shaped hemodialysis access was created between the brachial artery and vena cubiti media as a second choice. The youngest patient was 12 years old, whereas the oldest was 75. The mean follow-up period (+/-SD) for these patients was 10.4+/-2.53 months. Twelve patients are still using these fistulas successfully for hemodialysis (86.6%), whereas one patient died 7 months after the operation (6.7%). In one patient, the arteriovenous fistula failed 6 months after the operation (6.7%). Thrombosis due to hypotension occured in two cases (13.3%) and this was resolved by simple thrombectomy. One patient had an aneurysm over the vena cubiti media (6.6%). None of the patients had an infection. These results suggest that an end-to-side anastomosis between the brachial artery and, vena cubiti media can be used as a second choice for hemodialysis access in patients with end-stage renal disease.en_US
dc.identifier.doi10.1007/s10016-004-0053-2en_US
dc.identifier.endpage592en_US
dc.identifier.issn0890-5096en_US
dc.identifier.issue5en_US
dc.identifier.pmid15534739en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage589en_US
dc.identifier.urihttps://dx.doi.org/10.1007/s10016-004-0053-2
dc.identifier.urihttps://hdl.handle.net/20.500.12395/19281
dc.identifier.volume18en_US
dc.identifier.wosWOS:000223785100012en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherSPRINGERen_US
dc.relation.ispartofANNALS OF VASCULAR SURGERYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleVena cubiti media for creation of a loop-shaped arteriovenous fistula at the elbow regionen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
gormus2004 (1).pdf
Boyut:
124.08 KB
Biçim:
Adobe Portable Document Format
Açıklama: