Vena cubiti media for creation of a loop-shaped arteriovenous fistula at the elbow region
dc.contributor.author | Gormus, N | |
dc.contributor.author | Ozergin, U | |
dc.contributor.author | Ozpinar, C | |
dc.contributor.author | Solak, H | |
dc.date.accessioned | 2020-03-26T16:55:38Z | |
dc.date.available | 2020-03-26T16:55:38Z | |
dc.date.issued | 2004 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | Hemodialysis access is one of the major routes, for patients who need long-term hemodialysis. In this report, we tried a new secondary arteriovenous fistula technique. Between January 2000 and June 2003, hemodialysis access was created in more than 650 patients with end-stage renal failure at our institution. In 15 cases a loop-shaped hemodialysis access was created between the brachial artery and vena cubiti media as a second choice. The youngest patient was 12 years old, whereas the oldest was 75. The mean follow-up period (+/-SD) for these patients was 10.4+/-2.53 months. Twelve patients are still using these fistulas successfully for hemodialysis (86.6%), whereas one patient died 7 months after the operation (6.7%). In one patient, the arteriovenous fistula failed 6 months after the operation (6.7%). Thrombosis due to hypotension occured in two cases (13.3%) and this was resolved by simple thrombectomy. One patient had an aneurysm over the vena cubiti media (6.6%). None of the patients had an infection. These results suggest that an end-to-side anastomosis between the brachial artery and, vena cubiti media can be used as a second choice for hemodialysis access in patients with end-stage renal disease. | en_US |
dc.identifier.doi | 10.1007/s10016-004-0053-2 | en_US |
dc.identifier.endpage | 592 | en_US |
dc.identifier.issn | 0890-5096 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.pmid | 15534739 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 589 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1007/s10016-004-0053-2 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/19281 | |
dc.identifier.volume | 18 | en_US |
dc.identifier.wos | WOS:000223785100012 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | SPRINGER | en_US |
dc.relation.ispartof | ANNALS OF VASCULAR SURGERY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.title | Vena cubiti media for creation of a loop-shaped arteriovenous fistula at the elbow region | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- gormus2004 (1).pdf
- Boyut:
- 124.08 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama: