Evaluation of Osteoblastic Activity Around Dental Implants Using Bone Scintigraphy

dc.contributor.authorKalaycı, Abdullah
dc.contributor.authorDurmuş, Ercan
dc.contributor.authorTaştekin, Güngör
dc.contributor.authorIşık, Kubilay
dc.contributor.authorİnan, Özgür
dc.date.accessioned2020-03-26T17:48:36Z
dc.date.available2020-03-26T17:48:36Z
dc.date.issued2010
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractObjectives: The aim of this study was to evaluate the osteoblastic activity around delayloaded intraosseous dental implants using nuclear medicine imaging techniques. Material and methods: Seven totally edentulous patients (two females and five males, between 48 and 57 years of age) were included in the study. Two implants were inserted into mandibular canine regions and removable prostheses were produced after 3 months. Whole-body bone scintigraphies with 20 mCi technetium 99m labelled methylene diphosphonate were taken from the patients before implant insertion, 3 months after implant placement just before the prostheses were made and 1 year after implant placement. Standardized count/pixel (SC/P) rates were calculated for each patient. Preimplantation SC/P values were compared with the 3- and 12-month values. Three-month values were compared with the 12-month values as well. Results: SC/P rates in the third month were significantly higher (Po0.05) than preoperative values and the SC/P rates of the 12th month were significantly lower (Po0.05) than 3-month values. The SC/P rates of the 12th month were relatively higher than first scintigraphies but the difference was insignificant (P40.05). Conclusions: Within the limitations of this study, in which delayed loading was applied, we showed that osteoblastic activity persisted more in delay loaded implants than immediate and early loading. After 1 year, there was no cellular activity around two implants and this implied that two implants were sufficient for a total prosthesis.en_US
dc.identifier.citationKalaycı, A., Durmuş, E., Taştekin, G., Işık, K., İnan, Ö., (2010). Evaluation of Osteoblastic Activity Around Dental Implants Using Bone Scintigraphy. Clinical Oral Implants Research, (21), 209-212. Doi: 10.1111/j.1600-0501.2009.01822.x
dc.identifier.doi10.1111/j.1600-0501.2009.01822.xen_US
dc.identifier.endpage212en_US
dc.identifier.issn0905-7161en_US
dc.identifier.issn1600-0501en_US
dc.identifier.pmid20070753en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage209en_US
dc.identifier.urihttps://dx.doi.org/10.1111/j.1600-0501.2009.01822.x
dc.identifier.urihttps://hdl.handle.net/20.500.12395/24911
dc.identifier.volume21en_US
dc.identifier.wosWOS:000273548800010en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorKalaycı, Abdullah
dc.institutionauthorDurmuş, Ercan
dc.institutionauthorTaştekin, Güngör
dc.institutionauthorİnan, Özgür
dc.language.isoenen_US
dc.publisherWileyen_US
dc.relation.ispartofClinical Oral Implants Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectBone scintigraphyen_US
dc.subjectDental implantsen_US
dc.subjectOsteoblastic activityen_US
dc.titleEvaluation of Osteoblastic Activity Around Dental Implants Using Bone Scintigraphyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
4911.pdf
Boyut:
271.64 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası