Treatment of Posttraumatic Cubitus Varus With Corrective Supracondylar Humeral Osteotomies Using the Methyl Methacrylate External Fixator

dc.contributor.authorAcar, Mehmet Ali
dc.contributor.authorYıldırım, Serhat
dc.contributor.authorElmadağ, Nuh Mehmet
dc.contributor.authorŞenaran, Hakan
dc.contributor.authorOgün, Tunç C.
dc.date.accessioned2020-03-26T18:58:44Z
dc.date.available2020-03-26T18:58:44Z
dc.date.issued2014
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractBackground: In upper and lower extremity fractures and osteotomy fixation, the use of methyl methacrylate (MM) as an external fixator presents an alternative method. The primary aim of this retrospective study was to evaluate the midterm outcome of pediatric patients who underwent corrective humeral supracondylar lateral closing-wedge osteotomy, with the external fixation system composed of MM and multiplane K-wires. Methods: Fourteen consecutive cases with cubitus varus, who underwent corrective osteotomy with a limited lateral approach stabilized with MM and the multiplane K-wires external fixator system between January 2006 and May 2010, were retrospectively evaluated. Time of union, preoperative and postoperative elbow range of motion, and humeroulnar angle were measured. Results were rated as excellent, good, or poor, according to Bellemore criteria. Results: There were a total of 6 female patients and 8 male patients with a mean age of 5.7 years (range, 3 to 9 y). The mean follow-up period was 28.2 months (range, 24 to 48 mo). The mean humeroulnar angle was (-) 18.6 degrees preoperatively, and (+) 16.3 degrees at the final follow-up. Thirteen patients were evaluated as excellent and 1 patient as good, according to Bellemore criteria. Union was seen in all patients at mean 7 weeks (range, 6 to 8 wk). Pin tract infection was observed in 1 patient and treated with oral antibiotics. Loss of correction was not observed in any patient during follow-up. Conclusions: External fixation of corrective supracondylar humeral osteotomy with MM and multiplane K-wires is a practical, effective, reliable, and cheap alternative method that can be applied. Level of Evidence: Level IV. Retrospective study.en_US
dc.identifier.doi10.1097/BPO.0000000000000103en_US
dc.identifier.endpage259en_US
dc.identifier.issn0271-6798en_US
dc.identifier.issn1539-2570en_US
dc.identifier.issue3en_US
dc.identifier.pmid24096446en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage253en_US
dc.identifier.urihttps://dx.doi.org/10.1097/BPO.0000000000000103
dc.identifier.urihttps://hdl.handle.net/20.500.12395/31258
dc.identifier.volume34en_US
dc.identifier.wosWOS:000335698200005en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherLIPPINCOTT WILLIAMS & WILKINSen_US
dc.relation.ispartofJOURNAL OF PEDIATRIC ORTHOPAEDICSen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectmethyl methacrylateen_US
dc.subjectcubitus varusen_US
dc.subjectosteotomyen_US
dc.subjectsupracondylar fractureen_US
dc.subjectexternal fixatoren_US
dc.titleTreatment of Posttraumatic Cubitus Varus With Corrective Supracondylar Humeral Osteotomies Using the Methyl Methacrylate External Fixatoren_US
dc.typeArticleen_US

Dosyalar