Two-dimensional shear wave elastography in the assessment of salivary gland ınvolvement in primary sjogren's syndrome

dc.authorid0000-0001-7984-4326
dc.authorid0000-0002-1340-2477
dc.contributor.authorArslan, Serdar.
dc.contributor.authorDurmaz, Mehmet Sedat.
dc.contributor.authorErdogan, Hasan.
dc.contributor.authorEsmen, Serpil Ergulu.
dc.contributor.authorTurgut, Bekir.
dc.contributor.authorIyisoy, Mehmet Sinan.
dc.date.accessioned2020-03-26T20:19:41Z
dc.date.available2020-03-26T20:19:41Z
dc.date.issued2019
dc.departmentSelçuk Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.description.abstractObjectives The aim of this study was to investigate the diagnostic performance of two-dimensional (2D) shear wave elastography (SWE) in the assessment of salivary gland involvement in primary Sjogren's syndrome (pSS). Methods Fifty-three patients with pSS and 30 healthy volunteers were included. The echogenicity of all submandibular and parotid glands was evaluated with B-mode ultrasound, and their elasticity was assessed with 2D SWE. The mean and standard deviation of the shear wave speed and elasticity modes on 2D SWE were calculated. Results The mean shear wave speed and elasticity mode values for the submandibular and parotid glands were significantly higher in the patients with pSS (P < .05). The mean elasticity of the shear wave speed mode was best able to differentiate the parotid glands of patients with pSS from those of healthy volunteers at a cutoff value of 2.48 m/s, whereas the mean elasticity of the elasticity mode was best able to differentiate the submandibular glands of patients with pSS from those of healthy volunteers at a cutoff value of 21 kPa. Conclusions Two-dimensional SWE is an effective technique for assessment of the parenchyma of the salivary glands in patients with pSS and predicts interstitial fibrosis and the severity of histologic damage.en_US
dc.identifier.citationArslan, S., Durmaz, M. S., Erdogan, H., Esmen, S. E., Turgut, B., Iyisoy, M. S. (2019). Two-Dimensional Shear Wave Elastography in the Assessment of Salivary Gland Involvement in Primary Sjogren's Syndrome. Journal Of Ultrasound in Medicine, 39(5), 949- 956.
dc.identifier.doi10.1002/jum.15179en_US
dc.identifier.issn0278-4297en_US
dc.identifier.issn1550-9613en_US
dc.identifier.pmid31763717en_US
dc.identifier.urihttps://dx.doi.org/10.1002/jum.15179
dc.identifier.urihttps://hdl.handle.net/20.500.12395/38363
dc.identifier.wosWOS:000498295700001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDurmaz, Mehmet Sedat.
dc.language.isoenen_US
dc.publisherWILEYen_US
dc.relation.ispartofJOURNAL OF ULTRASOUND IN MEDICINEen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectsalivary glandsen_US
dc.subjectshear wave elastographyen_US
dc.subjectSjogren's syndromeen_US
dc.subjectultrasounden_US
dc.titleTwo-dimensional shear wave elastography in the assessment of salivary gland ınvolvement in primary sjogren's syndromeen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Serdar ARSLAN.pdf
Boyut:
6.58 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Full Text Access