Evaluation of the Effect of Four Self-Etching Adhesives on Dentin Permeability
dc.contributor.author | Orucoglu, Hasan | |
dc.contributor.author | Belli, Sema | |
dc.date.accessioned | 2020-03-26T17:38:38Z | |
dc.date.available | 2020-03-26T17:38:38Z | |
dc.date.issued | 2009 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | Objective: The aim of this study was to evaluate the effect of two two-step and two single-step self-etching adhesives on dentin permeability using a computerized fluid filtration (CFF) test method. Methodology: Forty recently extracted sound human molar teeth were sectioned at the mid level of the crown to obtain dentin discs of 1 +/- 0.2 mm. A total of 40 discs were obtained and randomly divided into four groups (n = 10). The permeability of the discs was measured using the CFF test method before and after application of the following self-etching adhesives: Hybrid Bond, G-Bond, AdheSE, and Protect Bond. Fluid movement measurements were made at 2-min intervals for 8 min, and a mean of the values obtained was calculated for each specimen. Results: The in vitro fluid conductance of dentin discs treated with Hybrid Bond and AdheSE were lower than the dentin discs treated with G-Bond and Protect Bond (p < 0.05.). Conclusion: 1-Treating dentin discs with self-etching adhesives caused significant reduction of dentin permeability. 2-All self-etching adhesives allowed diffusion of distilled water. However, AdheSE and Hybrid Bond showed the lowest permeability. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 90B: 110-115, 2009 | en_US |
dc.description.sponsorship | Scientific Research Projects (BAP) Coordinating Office of Selcuk UniversitySelcuk University | en_US |
dc.description.sponsorship | Contract grant sponsor: Scientific Research Projects (BAP) Coordinating Office of Selcuk University | en_US |
dc.identifier.doi | 10.1002/jbm.b.31259 | en_US |
dc.identifier.endpage | 115 | en_US |
dc.identifier.issn | 1552-4973 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 18988276 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 110 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1002/jbm.b.31259 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/23532 | |
dc.identifier.volume | 90B | en_US |
dc.identifier.wos | WOS:000267298500013 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | WILEY-LISS | en_US |
dc.relation.ispartof | JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | self-etching adhesives | en_US |
dc.subject | computerized fluid filtration test method | en_US |
dc.subject | dentin permeability | en_US |
dc.title | Evaluation of the Effect of Four Self-Etching Adhesives on Dentin Permeability | en_US |
dc.type | Article | en_US |