Comparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandibles

dc.contributor.authorOguz, Yener
dc.contributor.authorSaglam, Haci
dc.contributor.authorDolanmaz, Dogan
dc.contributor.authorUckan, Sina
dc.date.accessioned2020-03-26T18:14:00Z
dc.date.available2020-03-26T18:14:00Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractTen unembalmed adult sheep mandibles were used. The mandibles were sectioned in the midline, followed by sagittal split ramus osteotomies to obtain 20 hemimandibles. Each distal segment was advanced 5 mm on each hemimandible. Ten of the specimens were fixed with 4-hole extended 2.0 mm titanium miniplates and screws and the other 10 were fixed with 4-hole extended 2.0 min locking miniplates/screws. Each fixed specimen was mounted on a servo-hydraulic testing unit with the fixation device, and was tested to a range of forces of 0-140N. The displacement values (mm) under 20, 60, 120, and 140N were compared with the help of the Mann Whitney U-test, and there were no significant differences between them at any force tested. Locking miniplate/screws and standard miniplate/screws showed similar displacement values at the range of forces tested. (C) 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipAO Research Funden_US
dc.description.sponsorshipThis research project was supported financially by the AO Research Fund.en_US
dc.identifier.doi10.1016/j.bjoms.2009.11.014en_US
dc.identifier.endpage137en_US
dc.identifier.issn0266-4356en_US
dc.identifier.issue2en_US
dc.identifier.pmid20226575en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage135en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.bjoms.2009.11.014
dc.identifier.urihttps://hdl.handle.net/20.500.12395/26264
dc.identifier.volume49en_US
dc.identifier.wosWOS:000288629300011en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherCHURCHILL LIVINGSTONEen_US
dc.relation.ispartofBRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectSagittal split ramus osteotomyen_US
dc.subjectTitanium miniplatesen_US
dc.subjectLocking screw/platesen_US
dc.titleComparison of stability of 2.0 mm standard and 2.0 mm locking miniplate/screws for the fixation of sagittal split ramus osteotomy on sheep mandiblesen_US
dc.typeArticleen_US

Dosyalar