Silorane-Based Composite: Depth of Cure, Surface Hardness, Degree of Conversion, and Cervical Microleakage in Class II Cavities
Küçük Resim Yok
Tarih
2011
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
WILEY-BLACKWELL
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Objective: The purpose of this study was to determine the depth of cure, degree of conversion (DC), hardness, and cervical sealing ability of silorane-based composite (Filtek Silorane [FS; 3M, Seefeld, Germany]) and to compare with methacrylate-based composites (MBCs = Filtek Supreme XT [FSXT] and Filtek P60 [FP60]). Materials and Methods: The DC and hardness of every material were evaluated after 1, 7, and 30 days. The depth of cure was determined using the ISO 4049: 2000 standard. Microleakage was evaluated by measuring dye penetration across the gingival wall in cross-sectioned specimens. Results: FS showed lower depth of cure than FSXT and FP60. The DC of FS was significantly lower when compared to FP60 and FSXT. FS exhibited lower hardness than both FSXT and FP60 after 1 day of storage. The hardness of FS remained unchanged during the storage period. FS showed reduced microleakage scores compared to FSXT and showed similar microleakage scores compared to FP60. Conclusions: In conclusion, the DC and cure depth of FS are lower than those of MBCs. However, FS revealed stable hardness in water that is comparable to MBCs. The sealing ability of FS is similar or even better than that of MBCs.
Açıklama
Anahtar Kelimeler
Kaynak
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY
WoS Q Değeri
Q3
Scopus Q Değeri
Q1
Cilt
23
Sayı
5