Square wave voltammetry based on determination of copper (II) ions by polyluteolin- and polykaempferol-modified electrodes

dc.contributor.authorOztekin, Yasemin
dc.contributor.authorYazicigil, Zafer
dc.contributor.authorRamanaviciene, Almira
dc.contributor.authorRamanavicius, Arunas
dc.date.accessioned2020-03-26T18:16:18Z
dc.date.available2020-03-26T18:16:18Z
dc.date.issued2011
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractApplicability of square wave voltammetry for the determination of Cu(II) ions by PolyLut/GC and PolyKae/GC electrodes was evaluated in this study. For this luteolin and kaempferol were electrochemically polymerized on glassy carbon (GC) electrode surface in order to get polyluteolin and polykaempferol-modified glassy carbon electrodes (PolyLut/GC and PolyKae/GC, correspondingly). The formation of polyphenol layer on the GC electrode surface was evidenced by atomic force microscopy. Square wave voltammetry was found to be more sensitive in comparison with differential pulse voltammetry. It was determined that PolyLut/GC and PolyKae/GC electrodes offered great sensitivity towards Cu(II) ions with very low limit of detection, good reproducibility, sufficient stability and excellent selectivity of analytical signal. (C) 2011 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipSelcuk University Research FoundationSelcuk University [09401039]en_US
dc.description.sponsorshipThe authors would like to thank to Selcuk University Research Foundation for the financial support provided by under the project number 09401039.en_US
dc.identifier.doi10.1016/j.talanta.2011.05.005en_US
dc.identifier.endpage1027en_US
dc.identifier.issn0039-9140en_US
dc.identifier.issn1873-3573en_US
dc.identifier.issue2en_US
dc.identifier.pmid21726733en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage1020en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.talanta.2011.05.005
dc.identifier.urihttps://hdl.handle.net/20.500.12395/26845
dc.identifier.volume85en_US
dc.identifier.wosWOS:000293116600026en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.relation.ispartofTALANTAen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectElectrochemical determination of Copper(II)en_US
dc.subjectKaempferolen_US
dc.subjectLuteolinen_US
dc.subjectSquare wave voltammetryen_US
dc.subjectHeavy metalsen_US
dc.titleSquare wave voltammetry based on determination of copper (II) ions by polyluteolin- and polykaempferol-modified electrodesen_US
dc.typeArticleen_US

Dosyalar