Construction of an Amperometric Cholesterol Biosensor Based on DTP(aryl)aniline Conducting Polymer Bound Cholesterol Oxidase
dc.contributor.author | Cevik, Emre | |
dc.contributor.author | Cerit, Alaaddin | |
dc.contributor.author | Gazel, Nilay | |
dc.contributor.author | Yildiz, Huseyin Bekir | |
dc.date.accessioned | 2020-03-26T19:53:13Z | |
dc.date.available | 2020-03-26T19:53:13Z | |
dc.date.issued | 2018 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | In this study, an amperometric cholesterol biosensor was constructed based on cholesterol oxidase immobilized on a conducting 4-(4H-dithienol[3,2-b:2,3-d]pyrrole-4)aniline polymer, (DTP(aryl)aniline). Glassy carbon electrodes were covered with P(DTP(aryl)aniline) which is used for the wiring of enzyme to the electrode surface by using electro-polymerization. The electron transfer was successfully made by the bio-catalytic activity and possession of the unique morphology of the polymer allowed efficient immobilization of the cholesterol oxidase enzyme. Analytical performances; linear range, detection limit, limit of quantification and the Michaelis-Menten constant (K-m) of biosensor electrodes were obtained 2.0M-23.7M, 0.27M, 0.82M, 17,81M respectively. Biosensor optimization parameters: optimum pH, optimum temperature, stability test and response time were evaluated. The real sample and recovery studies were also performed in order to show applicability of the biosensing electrodes. | en_US |
dc.identifier.doi | 10.1002/elan.201800248 | en_US |
dc.identifier.endpage | 2453 | en_US |
dc.identifier.issn | 1040-0397 | en_US |
dc.identifier.issn | 1521-4109 | en_US |
dc.identifier.issue | 10 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 2445 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1002/elan.201800248 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/36442 | |
dc.identifier.volume | 30 | en_US |
dc.identifier.wos | WOS:000446660400031 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | WILEY-V C H VERLAG GMBH | en_US |
dc.relation.ispartof | ELECTROANALYSIS | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Cholesterol biosensor | en_US |
dc.subject | Cholesterol Oxidase | en_US |
dc.subject | DTP Conducting polymer | en_US |
dc.title | Construction of an Amperometric Cholesterol Biosensor Based on DTP(aryl)aniline Conducting Polymer Bound Cholesterol Oxidase | en_US |
dc.type | Article | en_US |