Evaluation of the Effect of Rotary Systems on Stresses in a New Testing Model Using a 3-Dimensional Printed Simulated Resin Root with an Oval-shaped Canal: A Finite Element Analysis Study

Küçük Resim Yok

Tarih

2016

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER SCIENCE INC

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Introduction: This finite element analysis study was aimed at evaluating the effects of rotary systems on stresses in photopolymerized resin root models with oval-shaped canals. Methods: Among the data collected by computed tomographic imaging, a mandibular second premolar tooth with an oval-shaped canal was selected, recorded as Digital Imaging and Communications in Medicine, and transferred to Materialise's Interactive Medical Image Control System software. Three-dimensional modeling was performed to produce photopolymerized resin root models. Root canals were prepared by OneShape (OS; MicroMega, Besancon, France); ProTaper Universal (PTU; Dentsply Tulsa Dental, Tulsa, OK); WaveOne (WO, Dentsply Maillefer, Ballaigues, Switzerland); Mtwo (MT; VDW, Munich, Germany); Twisted File (TF; Kerr Dental, Orange, CA); ProTaper Next (PTN, Dentsply Tulsa Dental), and hand files (HFs) (control). The models were scanned (micro computed tomographic imaging; SkyScan 1174; Kontich, Belgium), finite element analysis models were created, and stresses were calculated under 300-N loading (at a 45 degrees angle and vertically). Results: The maximum stress values were found to be higher when the roots were loaded at an angle. The range of the stress values was PTU > MT > WO > HF > PTN > OS > TF. The stresses were forwarded toward the apical area in the PTN, OS, and TF models. When loaded vertically, the highest maximum stress values were recorded in the WO model. High stress concentrations were observed at coronal, thus less stress was forwarded toward the apical, giving an advantage to the root. The range of the others was as follows: PTN >= PTU > MT > TF > OS >= HF. The TF model showed lower maximum stress values, whereas the HF model showed more homogenous stress distribution. Conclusions: Considering the stress distributions, and stress values within the models, it can be concluded that oval-shaped canals prepared by HFs and WO were less likely to result in root fracture.

Açıklama

Anahtar Kelimeler

Endodontics, finite element analysis, micro-computed tomography, oval shaped, root canal, rotary files, stress

Kaynak

JOURNAL OF ENDODONTICS

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

42

Sayı

8

Künye