Effect of light-emitting diode on bond strength of orthodontic brackets
dc.contributor.author | Usumez, S | |
dc.contributor.author | Buyukyilmaz, T | |
dc.contributor.author | Karaman, AI | |
dc.date.accessioned | 2020-03-26T16:48:18Z | |
dc.date.available | 2020-03-26T16:48:18Z | |
dc.date.issued | 2004 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | The aim of this study was to evaluate the effect of light-emitting diode (LED) light curing on shear bond strength (SBS) of orthodontic brackets bonded to teeth. Light exposure of 40 seconds from a conventional halogen-based light-curing unit was used as a control. Eighty human premolars were divided into four groups of 20 each. Brackets were bonded to acid-etched teeth with Transbond XT light-cured adhesive. In the first group, the adhesive was light cured for 40 seconds with a conventional halogen unit (XL3000, 3M). In the other three groups, adhesive was cured with a commercial LED unit (Elipar FreeLight, 3M ESPE) for 10, 20, or 40 seconds. SBS of brackets was measured on a universal testing machine and recorded in megapascals. Adhesive remnant index (ARI) scores were determined after failure of brackets. Data were analyzed using analysis of variance and chi-square tests. No statistically significant differences were found among the SBS values of halogen-based light-cured (13.1 +/- 3.1 MPa) and 20- and 40-second LED-cured (13.9 +/- 4.8 MPa and 12.7 +/- 5.1 MPa) specimens (P > .05). However, 10 seconds of LED curing yielded significantly lower SBS (P < .05). No statistically significant differences were found between the ARI scores among groups. The results of this study are promising for the orthodontic application of LED-curing units, but further compatibility and physical characteristic studies of various orthodontic adhesives and clinical trials should be performed before validation. | en_US |
dc.identifier.endpage | 263 | en_US |
dc.identifier.issn | 0003-3219 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.pmid | 15132454 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 259 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/19014 | |
dc.identifier.volume | 74 | en_US |
dc.identifier.wos | WOS:000220792600021 | en_US |
dc.identifier.wosquality | Q4 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | E H ANGLE EDUCATION RESEARCH FOUNDATION, INC | en_US |
dc.relation.ispartof | ANGLE ORTHODONTIST | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | LED | en_US |
dc.subject | bond strength | en_US |
dc.subject | bracket bonding | en_US |
dc.title | Effect of light-emitting diode on bond strength of orthodontic brackets | en_US |