dc.description.abstractObjectives. Tomeasure the temperature increase induced during thermocure lamp setting reaction of glass carbomer and to compare it with those induced by visible light curing of a resin-modified glass ionomer and a polyacid-modified composite resin in primary and permanent teeth. Materials and Methods. Nonretentive class I cavities were prepared in extracted primary and permanent molars. Glass carbomer (GC) was placed in the cavity and set at 60 degrees C for 60 sn using a special thermocure lamp. Resin-modified glass ionomer (RMGIC) and polyacid-modified composite resin (PMCR) were placed in the cavities and polymerized with an LED curing unit. Temperature increases during setting reactions were measured with a J-type thermocouple wire connected to a data logger. Data were examined using two-way analysis of variance and Tukey's honestly significant difference tests. Results. The use of GC resulted in temperature changes of 5.17 +/- 0.92 degrees C and 5.32 +/- 0.90 degrees C in primary and permanent teeth, respectively (p > 0.05). Temperature increases were greatest in the GC group, differing significantly fromthose in the PMCR group (p < 0.05). Conclusion. Temperature increases during polymerization and setting reactions of the materials were below the critical value in all groups. No difference was observed between primary and permanent teeth, regardless of the material used.en_US
dc.identifier.doi10.1155/2016/5173805en_US
dc.identifier.issn2314-6133en_US
dc.identifier.issn2314-6141en_US
dc.identifier.pmid28097136en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://dx.doi.org/10.1155/2016/5173805
dc.identifier.urihttps://hdl.handle.net/20.500.12395/33721
dc.identifier.wosWOS:000391601800001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherHINDAWI PUBLISHING CORPen_US
dc.relation.ispartofBIOMED RESEARCH INTERNATIONALen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleIntrapulpal Thermal Changes during Setting Reaction of Glass Carbomer (R) Using Thermocure Lampen_US