Clinical Characteristics and Outcome of Cardiovascular Implantable Electronic Device Infections in Turkey

dc.contributor.authorAydin, Mesut
dc.contributor.authorYildiz, Abdulkadir
dc.contributor.authorKaya, Zeynettin
dc.contributor.authorKaya, Zekeriya
dc.contributor.authorBasarir, Ahmet Ozgur
dc.contributor.authorCakmak, Nazmiye
dc.contributor.authorDonmez, Ibrahim
dc.date.accessioned2020-03-26T19:23:20Z
dc.date.available2020-03-26T19:23:20Z
dc.date.issued2016
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractInfection is one of the most devastating outcomes of cardiovascular implantable electronic device (CIED) implantation and is related to significant morbidity and mortality. In our country, there is no evaluation about CIED infection. Therefore, our aim was to investigate clinical characteristics and outcome of patients who had infection related to CIED implantation or replacement. The study included 144 consecutive patients with CIED infection treated at 11 major hospitals in Turkey from 2005 to 2014 retrospectively. We analyzed the medical files of all patients hospitalized with the diagnosis of CIED infection. Inclusion criteria were definite infection related to CIED implantation, replacement, or revision. Generator pocket infection, with or without bacteremia, was the most common clinical presentation, followed by CIED-related endocarditis. Coagulase-negative staphylococci and Staphylococcus aureus were the leading causative agents of CIED infection. Multivariate analysis showed that infective endocarditis and ejection fraction were the strongest predictors of in-hospital mortality.en_US
dc.identifier.doi10.1177/1076029614567310en_US
dc.identifier.endpage464en_US
dc.identifier.issn1076-0296en_US
dc.identifier.issn1938-2723en_US
dc.identifier.issue5en_US
dc.identifier.pmid25589093en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage459en_US
dc.identifier.urihttps://dx.doi.org/10.1177/1076029614567310
dc.identifier.urihttps://hdl.handle.net/20.500.12395/33358
dc.identifier.volume22en_US
dc.identifier.wosWOS:000377435200008en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherSAGE PUBLICATIONS INCen_US
dc.relation.ispartofCLINICAL AND APPLIED THROMBOSIS-HEMOSTASISen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectpacemakeren_US
dc.subjectimplantable defibrillatoren_US
dc.subjectcardiac resynchronization therapyen_US
dc.subjectinfectionen_US
dc.subjectpostoperative complicationsen_US
dc.titleClinical Characteristics and Outcome of Cardiovascular Implantable Electronic Device Infections in Turkeyen_US
dc.typeArticleen_US

Dosyalar