Hemolysis associated with pneumatic tube system transport for blood samples

Küçük Resim Yok

Tarih

2014

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

PROFESSIONAL MEDICAL PUBLICATIONS

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis.

Açıklama

Anahtar Kelimeler

Analysis, Blood, Biochemistry, Hematology

Kaynak

PAKISTAN JOURNAL OF MEDICAL SCIENCES

WoS Q Değeri

Q4

Scopus Q Değeri

Q3

Cilt

30

Sayı

1

Künye