A chemometric study: Automated flow injection analysis method for the quantitative determination of humic acid in Ilgm lignite

Küçük Resim Yok

Tarih

2016

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

ELSEVIER SCIENCE BV

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

A rapid, sensitive and provident flow injection analysis (FIA) method was developed within the framework of a chemometric approach for the quantification of humic acid (HA) in the lignite obtained from Ilgm, Konya, Turkey. The proposed method allows automatic determination of 60 samples per hour over a wide calibration range (0-2000 mg L-1, R-2: 0.9988) and needs only 10 mu L of sample at a flow rate of mobile phase (X-1), 2 mL min(-1); pH of mobile phase (X-2), 8, and system temperature (X-3), 20 degrees C. The limits of detection (LOD) and quantification (LOQ) were calculated as 9.18 mg L-1 and 30.60 mg L-1, respectively, and the relative standard deviation (RSD) for 500 mg L-1 HA was calculated as 3.44 (n: 9). It was revealed that the standard deviation (SD) values of the proposed FIA method are lower than those of the spectrophotometric method. (C) 2014 King Saud University. Production and hosting by Elsevier B.V.