A chemometric study: Automated flow injection analysis method for the quantitative determination of humic acid in Ilgm lignite
dc.contributor.author | Tarhan, Ismail | |
dc.contributor.author | Kara, Huseyin | |
dc.date.accessioned | 2020-03-26T19:22:54Z | |
dc.date.available | 2020-03-26T19:22:54Z | |
dc.date.issued | 2016 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | A rapid, sensitive and provident flow injection analysis (FIA) method was developed within the framework of a chemometric approach for the quantification of humic acid (HA) in the lignite obtained from Ilgm, Konya, Turkey. The proposed method allows automatic determination of 60 samples per hour over a wide calibration range (0-2000 mg L-1, R-2: 0.9988) and needs only 10 mu L of sample at a flow rate of mobile phase (X-1), 2 mL min(-1); pH of mobile phase (X-2), 8, and system temperature (X-3), 20 degrees C. The limits of detection (LOD) and quantification (LOQ) were calculated as 9.18 mg L-1 and 30.60 mg L-1, respectively, and the relative standard deviation (RSD) for 500 mg L-1 HA was calculated as 3.44 (n: 9). It was revealed that the standard deviation (SD) values of the proposed FIA method are lower than those of the spectrophotometric method. (C) 2014 King Saud University. Production and hosting by Elsevier B.V. | en_US |
dc.description.sponsorship | Scientific Research Projects Foundation of Selcuk University (SUBAP)Selcuk University [11101002]; TUBITAKTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [TUBITAK 2221] | en_US |
dc.description.sponsorship | The authors of this study thank the Scientific Research Projects Foundation of Selcuk University (SUBAP-Grant Number 11101002) for financial support of this work produced from a part of Ismail Tarhan's MsC Thesis. The authors would also like to thank TUBITAK for providing financial support to one of our research collaborator Professor Dr. S.T.H. Sherazi under TUBITAK 2221 Fellowship for Visiting Scientists and Scientists on Sabbatical Leave program. | en_US |
dc.identifier.doi | 10.1016/j.arabjc.2014.09.002 | en_US |
dc.identifier.endpage | 720 | en_US |
dc.identifier.issn | 1878-5352 | en_US |
dc.identifier.issn | 1878-5379 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 713 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.arabjc.2014.09.002 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/33171 | |
dc.identifier.volume | 9 | en_US |
dc.identifier.wos | WOS:000383114700014 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | ELSEVIER SCIENCE BV | en_US |
dc.relation.ispartof | ARABIAN JOURNAL OF CHEMISTRY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Chemometry | en_US |
dc.subject | Flow injection analysis | en_US |
dc.subject | Humic acid | en_US |
dc.subject | Lignite | en_US |
dc.title | A chemometric study: Automated flow injection analysis method for the quantitative determination of humic acid in Ilgm lignite | en_US |
dc.type | Article | en_US |