Effects of Different Curing Units and Luting Agents on Push-out Bond Strength of Translucent Posts
dc.contributor.author | Zorba, Yahya Orçun | |
dc.contributor.author | Erdemir, Ali | |
dc.contributor.author | Türkyılmaz, Ali | |
dc.contributor.author | Ünverdi Eldeniz, Ayçe | |
dc.date.accessioned | 2020-03-26T17:48:10Z | |
dc.date.available | 2020-03-26T17:48:10Z | |
dc.date.issued | 2010 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | Introduction: The aim of this study was to evaluate the effects of different curing units and 2 luting cements on the push-out bond strength of a translucent fiber post. Methods: Thirty maxillary incisor roots were endodontically treated. Post spaces were prepared, and the smear layers were removed. Posts (FRC Postec Plus) were luted with either a self-etch cement (Panavia F 2.0) or a self-adhesive cement (Maxcem). Luting agents were then light-activated with a quartz-tungsten-halogen, a blue light emitting diode, or a plasma-arc curing unit. Roots/cemented posts were transversally sectioned from coronal to apical. Push-out tests were performed, and data were analyzed by using three-way analysis of variance and Tukey tests. Results: Push-out bond strengths were significantly affected by the type of luting agent (P < .05) and root region (P < .05). The type of light source used in curing did not affect push-out bond strengths (P > .05). Conclusions: Self-adhesive resin cement provided higher bond strength than the self-etch cement when smear layer was removed before the post cementation. The push-out bond strength in the apical portion of the root was significantly lower than in the coronal region. The use of different curing units in the photoirradiation of dual-cured resin cement did not affect the retention of the fiber post as a result of the limited light transmission capability of this post. | en_US |
dc.description.sponsorship | Kirikkale University Scientific Project Research Foundation, TurkeyKirikkale University; Selcuk University, Scientific Research Project Coordination CenterSelcuk University | en_US |
dc.description.sponsorship | This study was supported by a grant-in-aid (2007-17) from the Kirikkale University Scientific Project Research Foundation, Turkey. This study was also partially supported by a grant given by Selcuk University, Scientific Research Project Coordination Center and conducted in the Research Laboratories of Faculty of Dentistry. | en_US |
dc.identifier.citation | Zorba, Y. O., Erdemir, A., Türkyılmaz, A., Ünverdi Eldeniz, A., (2010). Effects of Different Curing Units and Luting Agents on Push-out Bond Strength of Translucent Posts. Journal of Endodontics, 36(9), 1521-1525. Doi: 10.1016/j.joen.2010.04.026 | |
dc.identifier.doi | 10.1016/j.joen.2010.04.026 | en_US |
dc.identifier.endpage | 1525 | en_US |
dc.identifier.issn | 0099-2399 | en_US |
dc.identifier.issue | 9 | en_US |
dc.identifier.pmid | 20728720 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 1521 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.joen.2010.04.026 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/24838 | |
dc.identifier.volume | 36 | en_US |
dc.identifier.wos | WOS:000281657100015 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Ünverdi Eldeniz, Ayçe | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science Inc | en_US |
dc.relation.ispartof | Journal of Endodontics | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Curing units | en_US |
dc.subject | luting agents | en_US |
dc.subject | push out bond strength | en_US |
dc.title | Effects of Different Curing Units and Luting Agents on Push-out Bond Strength of Translucent Posts | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 4838.pdf
- Boyut:
- 1.19 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası