Determination of the Heart Rate Deflection Point by The Dmax Method

dc.contributor.authorKara, Mehmet
dc.contributor.authorGökbel, Hakkı
dc.contributor.authorBediz, Cem
dc.contributor.authorErgene, Neyhan
dc.contributor.authorÜçok, Kağan
dc.contributor.authorUysal, Hüseyin
dc.date.accessioned2020-03-26T16:24:46Z
dc.date.available2020-03-26T16:24:46Z
dc.date.issued1996
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractObjective, Conconi et al, proposed that the point where heart rate departed from linearity in an incremental exercise test was a good indicator of the anaerobic: threshold, However, the heart rate deflection points (HRDPs) can not be determined in many subjects, The aim of this study was to determine the heart rate deflection point by the Dmax method and to compare it with the conventional linear method, Setting. The study was performed in the Exercise Physiology Laboratory in the Faculty of Medicine, Selcuk University, Participants, Thirthy-two untrained males (aged 18-22) performed a maximal exercise test on a cycle ergometer, Results. The deflection from linearity of HR could not be detected in nine subjects (28%) by the linear method, The HRDPs could be detected in all subjects by the Dmax method, It was observed that the HR values in the HRDPs determined by both methods were close to the maximal HR values (approximately 90% of maximum), There were high correlations and no differences (p more than 0.05) between the deflection points expressed as oxygen uptake, HR and work rate determined by two methods (correlation coefficients 0.93, 0.93, 0.97, respectively, p less than 0.001), Conclusions. The Dmax method is more useful than linear method, The HRDPs of all the people can easily and objectively be found by this method.en_US
dc.identifier.citationKara, M., Gökbel, H., Bediz, C., Ergene, N., Üçok, K., Uysal, H., (1996). Determination of the Heart Rate Deflection Point by The Dmax Method. Journal Of Sports Medicine and Physical Fitness, 36(1), 31-34.
dc.identifier.endpage34en_US
dc.identifier.issn0022-4707en_US
dc.identifier.issue1en_US
dc.identifier.pmid8699835en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage31en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12395/16383
dc.identifier.volume36en_US
dc.identifier.wosWOS:A1996UT93100005en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorKara, Mehmet
dc.institutionauthorGökbel, Hakkı
dc.institutionauthorBediz, Cem
dc.institutionauthorErgene, Neyhan
dc.institutionauthorÜçok, Kağan
dc.institutionauthorUysal, Hüseyin
dc.language.isoenen_US
dc.publisherEdizioni Minerva Medicaen_US
dc.relation.ispartofJournal Of Sports Medicine And Physical Fitnessen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectanaerobic thresholden_US
dc.subjectheart rate deflection pointen_US
dc.subjectDmax methoden_US
dc.titleDetermination of the Heart Rate Deflection Point by The Dmax Methoden_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Determinationoftheheartrate.pdf
Boyut:
2.99 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası