Bond Strengths of Porcelain Laminate Veneers to Tooth Surfaces Prepared With Acid and Er,cr : Ysgg Laser Etching

dc.contributor.authorÜşümez, Aslıhan
dc.contributor.authorAykent, Filiz
dc.date.accessioned2020-03-26T16:45:27Z
dc.date.available2020-03-26T16:45:27Z
dc.date.issued2003
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractStatement of problem. The erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) hydrokinetic laser system has been successful in the ablation of dental tissues. It has been reported that this system is also useful for preparing tooth surfaces for adhesion, but results to date have been controversial. Purpose. This in vitro study evaluated the bond strengths of porcelain laminate veneers to tooth surfaces after etching with acid and Er,Cr:YSGG laser conditioning. Material and method. Forty extracted caries- and restoration-free human maxillary central incisors were used. The teeth were sectioned 2 mm below the cementoenamel junction. The crowns were embedded in autopolymerizing acrylic resin with the labial surfaces facing up. The labial surfaces were prepared with .05 mm reduction to receive porcelain veneers. The teeth were divided into 4 groups of 10 specimens. Thirty specimens received 1 of the following Surface treatments before the bonding of IPS Empress 2 laminate veneers: (1) laser radiation from an Er,Cr:YSGG laser unit; (2) 37% orthophosphoric acid; and (3) 10% maleic acid. Ten specimens received no surface treatment and served as the control group. The veneers were bonded with dual-polymerizing resin, Variolink II. One microtensile specimen from each of the cervical and incisal thirds measuring 1.2 x 1.2 mm was prepared with a slow-speed diamond saw sectioning machine with a diamond-rim blade. These specimens were attached to opposing arms of the microtensile testing device with cyanoacrylate adhesive and fractured under tension at a crosshead speed of 1 mm/min, and the maximum load at fracture (Kg) was recorded. The data were analyzed with a 2-way analysis of variance and Tukey HSD tests (alpha=.05). Results. No statistically significant differences were found among the bond strengths of veneers bonded to tooth surfaces etched wish Er,Cr:YSGG laser (12.1 +/- 4.4 MPa), 37% orthophosphoric acid (13 +/- 6.5 MPa), and 10% maleic acid (10.6 +/- 5.6 MPa). The control group demonstrated the lowest bond strength values in all test groups. Statistically significant differences were found between the bond strengths of cervical and incisal sections (P<.001). Conclusion. In vitro microtensile bond strengths of porcelain laminate veneers bonded to tooth surfaces that were laser-etched showed results similar to orthophosphoric acid or maleic acid etched tooth surfaces.en_US
dc.identifier.citationÜşümez, A., Aykent, F., (2003). Bond Strengths of Porcelain Laminate Veneers to Tooth Surfaces Prepared With Acid and Er,cr : Ysgg Laser Etching. Journal of Prosthetic Dentistry, 90(1), 24-30. Doi: 10.1016/S0022-3913(03)00235-X
dc.identifier.doi10.1016/S0022-3913(03)00235-Xen_US
dc.identifier.endpage30en_US
dc.identifier.issn0022-3913en_US
dc.identifier.issn1097-6841en_US
dc.identifier.issue1en_US
dc.identifier.pmid12869971en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage24en_US
dc.identifier.urihttps://dx.doi.org/10.1016/S0022-3913(03)00235-X
dc.identifier.urihttps://hdl.handle.net/20.500.12395/18379
dc.identifier.volume90en_US
dc.identifier.wosWOS:000184279300006en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorÜşümez, Aslıhan
dc.institutionauthorAykent, Filiz
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.titleBond Strengths of Porcelain Laminate Veneers to Tooth Surfaces Prepared With Acid and Er,cr : Ysgg Laser Etchingen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
usumez2003 (2).pdf
Boyut:
434.68 KB
Biçim:
Adobe Portable Document Format
Açıklama: