Is Urinary Bladder Pressure a Sensitive Indicator of Intra-Abdominal Pressure?

Yükleniyor...
Küçük Resim

Tarih

1998

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

GEORG THIEME VERLAG

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Background and Study Aims: The accuracy of transurethral bladder catheter pressure in reflecting intra-abdominal pressure is well defined in experimental studies and case reports but not in controlled clinical trials. Patients and Methods: We compared bladder pressure with insufflator pressure during laparoscopic cholecystectomy in 40 patients. Measurements were made at four pressure levels of the insufflator: 0, 5, 10 and 15 mmHg. Results: When the insufflator displayed 0, 5, 10, and 15 mmHg (0, 6.8, 13.6 and 20.4 cmH(2)O), and the mean bladder pressures measured 2.5 +/- 1.4, 7.3 +/- 1.5, 12.9 +/- 1.6 and 19.7 +/- 1.5 cmH(2)O, respectively, The two measurements correlated well with each other (r = 0.973, P < 0.0001). Conclusion: We concluded that bladder pressure measured by transurethral catheter was equal to insufflator pressure during laparoscopy, and that this was a valid indicator of intra-abdominal pressure.

Açıklama

Anahtar Kelimeler

Kaynak

Endoscopy

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

30

Sayı

9

Künye

Yol, S., Kartal, A., Tatkan, Y., Tavlı, S., (1998). Is Urinary Bladder Pressure a Sensitive Indicator of Intra-Abdominal Pressure?. Endoscopy, 30(9), 778-780. doi: 10.1055/s-2007-1001421