Determination of Chlorobenzenes in Water by Drop-Based Liquid-Phase Microextraction and Gas Chromatography-Electron Capture Detection
dc.contributor.author | Tor, Ali | |
dc.date.accessioned | 2020-03-26T17:03:20Z | |
dc.date.available | 2020-03-26T17:03:20Z | |
dc.date.issued | 2006 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | A drop-based liquid phase microextraction and gas chromatographic-electron capture detection (GC-ECD) method was described for the determination of chlorobenzenes including chlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene and 1,2,3-trichlorobenzene in 5 ml of water. The method used 2 mu l of n-hexane as extraction solvent, 5 min extraction time, a stirring rate of 600 rpm and sample ionic strength of 3 M maintained with sodium chloride at 25 degrees C (ambient temperature). The limits of detection (LODs) ranged from 0.004 mu g l(-1) (for 1,3-dichlorobenzene) to 0.008 mu g l(-1) (for monochlorobenzene). The dynamic linear range for all investigated chlorobenzenes was 1-50 mu g l(-1). Recoveries of chlorobenzenes from fortified distilled water are over 90% for three different fortification levels (5, 15 and 45 mu g l(-1)) and relative standard deviations of the recoveries are below 6%. Analysis of fortified (5 mu g l(-1)) real water samples revealed that matrices had no adverse effect on extraction efficiency of proposed method. The recovery of fortified real water samples was from 90 to 94% with relative standard deviations below 6%. | en_US |
dc.identifier.citation | Tor, A., (2006). Determination of Chlorobenzenes in Water by Drop-Based Liquid-Phase Microextraction and Gas Chromatography-Electron Capture Detection. Journal of Chromatography a, (1125), 129-132. Doi: 10.1016/j.chroma.2006.06.081 | |
dc.identifier.doi | 10.1016/j.chroma.2006.06.081 | en_US |
dc.identifier.endpage | 132 | en_US |
dc.identifier.issn | 0021-9673 | en_US |
dc.identifier.pmid | 16859695 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 129 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1016/j.chroma.2006.06.081 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/20425 | |
dc.identifier.volume | 1125 | en_US |
dc.identifier.wos | WOS:000239706400013 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Tor, Ali | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Science Bv | en_US |
dc.relation.ispartof | Journal of Chromatography a | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | chlorobenzenes | en_US |
dc.subject | liquid-phase microextraction | en_US |
dc.subject | water analysis | en_US |
dc.title | Determination of Chlorobenzenes in Water by Drop-Based Liquid-Phase Microextraction and Gas Chromatography-Electron Capture Detection | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 20425.pdf
- Boyut:
- 123.21 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası