Determination of Chlorobenzenes in Water by Drop-Based Liquid-Phase Microextraction and Gas Chromatography-Electron Capture Detection

dc.contributor.authorTor, Ali
dc.date.accessioned2020-03-26T17:03:20Z
dc.date.available2020-03-26T17:03:20Z
dc.date.issued2006
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractA drop-based liquid phase microextraction and gas chromatographic-electron capture detection (GC-ECD) method was described for the determination of chlorobenzenes including chlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene and 1,2,3-trichlorobenzene in 5 ml of water. The method used 2 mu l of n-hexane as extraction solvent, 5 min extraction time, a stirring rate of 600 rpm and sample ionic strength of 3 M maintained with sodium chloride at 25 degrees C (ambient temperature). The limits of detection (LODs) ranged from 0.004 mu g l(-1) (for 1,3-dichlorobenzene) to 0.008 mu g l(-1) (for monochlorobenzene). The dynamic linear range for all investigated chlorobenzenes was 1-50 mu g l(-1). Recoveries of chlorobenzenes from fortified distilled water are over 90% for three different fortification levels (5, 15 and 45 mu g l(-1)) and relative standard deviations of the recoveries are below 6%. Analysis of fortified (5 mu g l(-1)) real water samples revealed that matrices had no adverse effect on extraction efficiency of proposed method. The recovery of fortified real water samples was from 90 to 94% with relative standard deviations below 6%.en_US
dc.identifier.citationTor, A., (2006). Determination of Chlorobenzenes in Water by Drop-Based Liquid-Phase Microextraction and Gas Chromatography-Electron Capture Detection. Journal of Chromatography a, (1125), 129-132. Doi: 10.1016/j.chroma.2006.06.081
dc.identifier.doi10.1016/j.chroma.2006.06.081en_US
dc.identifier.endpage132en_US
dc.identifier.issn0021-9673en_US
dc.identifier.pmid16859695en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage129en_US
dc.identifier.urihttps://dx.doi.org/10.1016/j.chroma.2006.06.081
dc.identifier.urihttps://hdl.handle.net/20.500.12395/20425
dc.identifier.volume1125en_US
dc.identifier.wosWOS:000239706400013en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorTor, Ali
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofJournal of Chromatography aen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectchlorobenzenesen_US
dc.subjectliquid-phase microextractionen_US
dc.subjectwater analysisen_US
dc.titleDetermination of Chlorobenzenes in Water by Drop-Based Liquid-Phase Microextraction and Gas Chromatography-Electron Capture Detectionen_US