Implant-Retained Auricular Prosthesis

dc.contributor.authorDemir, Necla
dc.contributor.authorMalkoç, Meral Arslan
dc.contributor.authorÖztürk, A. Nilgün
dc.contributor.authorTosun, Zekeriya
dc.date.accessioned2020-03-26T17:49:06Z
dc.date.available2020-03-26T17:49:06Z
dc.date.issued2010
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractAuricular defects may result from congenital malformations, injuries from motor vehicle crashes, trauma, or tumor resections. An auricular prosthesis was fabricated for a patient who had an injury from a motor vehicle crash. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This prosthesis was acceptable to the patient because of excellent support, retentive abilities, and the patient's appearance.en_US
dc.identifier.citationDemir, N., Malkoç, M. A., Öztürk, A. N., Tosun, Z., (2010). Implant-Retained Auricular Prosthesis. Journal of Craniofacial Surgery, 21(6), 1795-1797. Doi: 10.1097/SCS.0b013e3181f404a6
dc.identifier.doi10.1097/SCS.0b013e3181f404a6en_US
dc.identifier.endpage1797en_US
dc.identifier.issn1049-2275en_US
dc.identifier.issue6en_US
dc.identifier.pmid21119423en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1795en_US
dc.identifier.urihttps://dx.doi.org/10.1097/SCS.0b013e3181f404a6
dc.identifier.urihttps://hdl.handle.net/20.500.12395/24990
dc.identifier.volume21en_US
dc.identifier.wosWOS:000284829800030en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDemir, Necla
dc.institutionauthorMalkoç, Meral Arslan
dc.institutionauthorÖztürk, A. Nilgün
dc.institutionauthorTosun, Zekeriya
dc.language.isoenen_US
dc.publisherLippincott Williams & Wilkinsen_US
dc.relation.ispartofJournal of Craniofacial Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectMaxillofacial prosthesisen_US
dc.subjectauricular prosthesisen_US
dc.subjectimplant-retained prosthesisen_US
dc.subjectauricular defectsen_US
dc.subjectosseointegrated auricular implantsen_US
dc.titleImplant-Retained Auricular Prosthesisen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
4990.pdf
Boyut:
709.92 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası