Implant-Retained Auricular Prosthesis
dc.contributor.author | Demir, Necla | |
dc.contributor.author | Malkoç, Meral Arslan | |
dc.contributor.author | Öztürk, A. Nilgün | |
dc.contributor.author | Tosun, Zekeriya | |
dc.date.accessioned | 2020-03-26T17:49:06Z | |
dc.date.available | 2020-03-26T17:49:06Z | |
dc.date.issued | 2010 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | Auricular defects may result from congenital malformations, injuries from motor vehicle crashes, trauma, or tumor resections. An auricular prosthesis was fabricated for a patient who had an injury from a motor vehicle crash. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This prosthesis was acceptable to the patient because of excellent support, retentive abilities, and the patient's appearance. | en_US |
dc.identifier.citation | Demir, N., Malkoç, M. A., Öztürk, A. N., Tosun, Z., (2010). Implant-Retained Auricular Prosthesis. Journal of Craniofacial Surgery, 21(6), 1795-1797. Doi: 10.1097/SCS.0b013e3181f404a6 | |
dc.identifier.doi | 10.1097/SCS.0b013e3181f404a6 | en_US |
dc.identifier.endpage | 1797 | en_US |
dc.identifier.issn | 1049-2275 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.pmid | 21119423 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 1795 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1097/SCS.0b013e3181f404a6 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/24990 | |
dc.identifier.volume | 21 | en_US |
dc.identifier.wos | WOS:000284829800030 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Demir, Necla | |
dc.institutionauthor | Malkoç, Meral Arslan | |
dc.institutionauthor | Öztürk, A. Nilgün | |
dc.institutionauthor | Tosun, Zekeriya | |
dc.language.iso | en | en_US |
dc.publisher | Lippincott Williams & Wilkins | en_US |
dc.relation.ispartof | Journal of Craniofacial Surgery | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Maxillofacial prosthesis | en_US |
dc.subject | auricular prosthesis | en_US |
dc.subject | implant-retained prosthesis | en_US |
dc.subject | auricular defects | en_US |
dc.subject | osseointegrated auricular implants | en_US |
dc.title | Implant-Retained Auricular Prosthesis | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 4990.pdf
- Boyut:
- 709.92 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası