Apical Microleakage of Root-End Cavities Prepared by Er, Cr: YSGG Laser

dc.contributor.authorÇalışkan, Mehmet Kemal
dc.contributor.authorParlar, Nilay Kara
dc.contributor.authorOruçoğlu, Hasan
dc.contributor.authorAydın, Berdan
dc.date.accessioned2020-03-26T17:47:07Z
dc.date.available2020-03-26T17:47:07Z
dc.date.issued2010
dc.departmentSelçuk Üniversitesien_US
dc.description.abstractThe aim of this study is to assess the apical microleakage of the composite filled root-end cavities prepared by an Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser. Fifty-five maxillary incisor teeth were enlarged and filled. Following the apical resection, root-end cavities were prepared using conventional methods: either using a bur (n = 30) or an ultrasonic retrotip (n = 15). Root-end cavities of the 15 teeth in the bur group were finished with the laser at 3.5 W. All root-end cavities were filled using two-step self-etching primer and composite resin. After 4 months of storage, apical microleakage was measured by a fluid filtration method. Microleakage of composite filled root-end cavities that were prepared by Er, Cr: YSGG was significantly larger than those made by conventional methods (p < 0.05). In conclusion, using the Er, Cr: YSGG laser has no advantages over conventional root-end cavity preparation methods when a composite filling material is used to seal root-end cavities.en_US
dc.identifier.citationÇalışkan, M. K., Parlar, N. K., Oruçoğlu, H., Aydın, B., (2010). Apical Microleakage of Root-End Cavities Prepared by Er, Cr: YSGG Laser. Lasers in Medical Science, (25), 145-150. Doi: 10.1007/s10103-009-0661-8
dc.identifier.doi10.1007/s10103-009-0661-8en_US
dc.identifier.endpage150en_US
dc.identifier.issn0268-8921en_US
dc.identifier.issn1435-604Xen_US
dc.identifier.pmid19277818en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage145en_US
dc.identifier.urihttps://dx.doi.org/10.1007/s10103-009-0661-8
dc.identifier.urihttps://hdl.handle.net/20.500.12395/24626
dc.identifier.volume25en_US
dc.identifier.wosWOS:000272175000019en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorOruçoğlu, Hasan
dc.language.isoenen_US
dc.publisherSpringer London Ltden_US
dc.relation.ispartofLasers in Medical Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.selcuk20240510_oaigen_US
dc.subjectEr, Cr, YSGG laseren_US
dc.subjectRoot-end cavityen_US
dc.subjectMicroleakageen_US
dc.subjectFluid filtrationen_US
dc.subjectUltrasonic retrotipen_US
dc.titleApical Microleakage of Root-End Cavities Prepared by Er, Cr: YSGG Laseren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
4626.pdf
Boyut:
163.4 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası