Apical Microleakage of Root-End Cavities Prepared by Er, Cr: YSGG Laser
dc.contributor.author | Çalışkan, Mehmet Kemal | |
dc.contributor.author | Parlar, Nilay Kara | |
dc.contributor.author | Oruçoğlu, Hasan | |
dc.contributor.author | Aydın, Berdan | |
dc.date.accessioned | 2020-03-26T17:47:07Z | |
dc.date.available | 2020-03-26T17:47:07Z | |
dc.date.issued | 2010 | |
dc.department | Selçuk Üniversitesi | en_US |
dc.description.abstract | The aim of this study is to assess the apical microleakage of the composite filled root-end cavities prepared by an Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser. Fifty-five maxillary incisor teeth were enlarged and filled. Following the apical resection, root-end cavities were prepared using conventional methods: either using a bur (n = 30) or an ultrasonic retrotip (n = 15). Root-end cavities of the 15 teeth in the bur group were finished with the laser at 3.5 W. All root-end cavities were filled using two-step self-etching primer and composite resin. After 4 months of storage, apical microleakage was measured by a fluid filtration method. Microleakage of composite filled root-end cavities that were prepared by Er, Cr: YSGG was significantly larger than those made by conventional methods (p < 0.05). In conclusion, using the Er, Cr: YSGG laser has no advantages over conventional root-end cavity preparation methods when a composite filling material is used to seal root-end cavities. | en_US |
dc.identifier.citation | Çalışkan, M. K., Parlar, N. K., Oruçoğlu, H., Aydın, B., (2010). Apical Microleakage of Root-End Cavities Prepared by Er, Cr: YSGG Laser. Lasers in Medical Science, (25), 145-150. Doi: 10.1007/s10103-009-0661-8 | |
dc.identifier.doi | 10.1007/s10103-009-0661-8 | en_US |
dc.identifier.endpage | 150 | en_US |
dc.identifier.issn | 0268-8921 | en_US |
dc.identifier.issn | 1435-604X | en_US |
dc.identifier.pmid | 19277818 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 145 | en_US |
dc.identifier.uri | https://dx.doi.org/10.1007/s10103-009-0661-8 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12395/24626 | |
dc.identifier.volume | 25 | en_US |
dc.identifier.wos | WOS:000272175000019 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Oruçoğlu, Hasan | |
dc.language.iso | en | en_US |
dc.publisher | Springer London Ltd | en_US |
dc.relation.ispartof | Lasers in Medical Science | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.selcuk | 20240510_oaig | en_US |
dc.subject | Er, Cr, YSGG laser | en_US |
dc.subject | Root-end cavity | en_US |
dc.subject | Microleakage | en_US |
dc.subject | Fluid filtration | en_US |
dc.subject | Ultrasonic retrotip | en_US |
dc.title | Apical Microleakage of Root-End Cavities Prepared by Er, Cr: YSGG Laser | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 4626.pdf
- Boyut:
- 163.4 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası